![Savant SmartEnergy SEM-1024 Deployment Manual Download Page 13](http://html1.mh-extra.com/html/savant/smartenergy-sem-1024/smartenergy-sem-1024_deployment-manual_1203600013.webp)
Savant Standalone Energy Monitor Deployment Guide
Copyright 2020 Savant Systems, Inc
009-1928-01 | 200828
13 of 24
4.2. Energy Monitor Data Table
The Energy Monitor Data Table is required for the Pro App to populate energy data. The following examples will demonstrate how to configure the
Energy Monitor Data Table. To access the Energy Monitor Data Table from an open Blueprint configuration go to
Tools > Settings > Energy Monitor…
.
For more information on the fields in this data table see
Appendix B: Energy Monitor Data Table Index
.
Add Circuit (SEM-2015)
This example demonstrates how to measure the main feed for the house. A typical single phase system will have 2 legs. The process for adding any
standard circuit is the same except the Classification is different based on what is being added. Then number of phase channels is based on the
number of slots the breaker uses in the panel.
From an open Blueprint configuration do the following:
1.
Go to
Tools > Settings > Energy Monitor…
.
2. Click the +.
Add for SEM2015
Add for SEM1024
2
3
3. Select the Energy Monitor to be used.
4. Double click on the Circuit Description.
Enabled Circuit Description
Classification
Group Image
Monitoring Device Channel Size Voltage Source Parent Circuit Control Savant Zone
Group
Image
Production Type
Main Power
None
Feed
SEM2015
1
None
Choose...
Utiliy Ro...
Phase 1 Channel
4
6
7
8
9
10
5. Enter the name for this circuit.
6. Select the Classification.
7. Select an Image for the circuit.
8. Select a Group (Optional).
9. Select the Channel.
10. Select the Savant Zone.
11. Select the Phase 1 Channel
12. Click the button at the bottom of the window.
13. Repeat step 9 for the Second Phase Channel. The image below shows the finished entry.
Enabled Circuit Description
Classification
Group Image
Monitoring Device Channel Size Voltage Source Parent Circuit Control Savant Zone
Group
Image
Production Type
Main Power
None
Feed
SEM2015
1
None
Choose...
2
Utiliy Ro...
Phase 1 Channel
Phase 2 Channel
IMPORTANT!
When configuring SEM-2015 devices, the size and voltage source must be defined within the component’s web UI. Refer to the
section below for details.