Savant SmartEnergy SEM-1024 Deployment Manual Download Page 3

Savant Standalone Energy Monitor Deployment Guide

Copyright 2020 Savant Systems, Inc

009-1928-01  |  200828

3     of     24

Important Safety Information - Read First

Before installing, configuring, or operating any equipment, Savant recommends 

that each dealer, integrator, installer, etc. access and read all relevant technical 

documentation.  Savant technical documentation can be located by visiting 

Savant.com.  Vendor documentation is supplied with the equipment.

Read and understand all safety instructions, cautions, and warnings in this 

document and the labels on the equipment.

Safety Statements

All safety instructions below must be read, understood, and carefully followed 

under all applicable circumstances when working with any Savant equipment.
1. 

Follow all input power ratings marked on product near power input!

2. 

If fuse replacement is required, replacement fuse should match fuse 

rating marked on the product.

3. 

Do not use equipment near water.

4. 

Clean only with dry cloth.

5. 

Do not block any ventilation openings or install near any heat sources 

such as heat registers, stoves, radiators, amplifiers, etc.

6. 

Refer all servicing to qualified service personnel. Servicing is required 

when any part of the apparatus has been damaged in any way, or fails to 

operate normally for any reason.

7. 

Use only attachments/accessories specified by the manufacturer, 

following all relevant safety precautions for any such attachments/

accessories.

8. 

For applicable equipment, use the included power cord with the 

grounding prong intact to insure proper grounding of the device.

9. 

If the provided plug does not fit the desired outlet, contact a licensed 

electrician to replace the obsolete outlet.

10.  Protect any power cord from being walked on, pinched, strained, or 

otherwise potentially damaged, especially at the outlet or device 

connections.

11. 

Disconnect any outlet powered apparatus from its power source during 

lightning storms or when unused for long periods of time.

12. 

To completely disconnect equipment from AC mains power, disconnect 

the power supply cord plug from the AC receptacle on the device.

13. 

For any hardwired or fixed in-wall apparatus, carefully follow all wiring 

diagrams and instructions. All electrical wiring and servicing should be 

performed by a properly licensed electrician.

Safety Classifications In this Document

NOTE

:

Provides special information for installing, 

configuring, and operating the equipment.

 

IMPORTANT!

Provides special information that is critical to 

installing, configuring, and operating the equipment.

 

CAUTION!

Provides special information for avoiding situations 

that may cause damage to equipment.

 

WARNING!

Provides special information for avoiding situations 

that may cause physical danger to the installer, end 

user, etc.

Electric Shock Prevention

 ELECTRIC 

SHOCK!

The source power poses an electric shock hazard 

that has the potential to cause serious injury to 

installers and end users.

 ELECTRICAL 

DISCONNECT

:

The source power outlet and power supply input 

power sockets should be easily accessible to 

disconnect power in the event of an electrical hazard 

or malfunction.

Weight Injury Prevention

 WEIGHT INJURY!

Installing some of the Savant equipment requires two 

installers to ensure safe handling during installation. 

Failure to use two installers may result in injury.

Summary of Contents for SmartEnergy SEM-1024

Page 1: ...Monitors are connected to a home s existing electrical panel using clip on current transformers and to the Savant Host via the local network They allow the user to monitor all aspects of energy usage...

Page 2: ...Three Phase Consumption Only 6 2 3 Single Phase with Power Generation 7 3 Installation 8 3 1 Flat Surface 8 SEM 2015 8 SEM 1024 8 3 2 Din Rail 9 3 3 Voltage Transformers 10 3 4 Current Transformers 11...

Page 3: ...device 9 If the provided plug does not fit the desired outlet contact a licensed electrician to replace the obsolete outlet 10 Protect any power cord from being walked on pinched strained or otherwise...

Page 4: ...page can be used as a checklist to mark progress as steps are completed Review product specifications and connection details See the device s Quick Reference Guide on the Savant Customer Community Ins...

Page 5: ...eployment Guide Copyright 2020 Savant Systems Inc 009 1928 01 200828 5 of 24 2 System Diagrams 2 1 Single Phase Consumption Only Typical 200 Amp Service Power from Utility Current Transformers Voltage...

Page 6: ...ant Standalone Energy Monitor Deployment Guide Copyright 2020 Savant Systems Inc 009 1928 01 200828 6 of 24 2 2 Three Phase Consumption Only Current Transformers Voltage Transformers Main Branch Monit...

Page 7: ...ds true for Wind Geothermal or Auxiliary Generators Power from Utility Current Transformers Solar Voltage Transformers Main Branch Monitors Inverter s TIP The diagram above shows one example of how to...

Page 8: ...ilable wall anchors can be used SEM 1024 Mounts to a wall or similar surface using the included chassis mounted side brackets and supplied M3 x 8mm flat head screws Mount chassis in a place that is dr...

Page 9: ...ed universal din rail clip To install using a Din Rail do the following 1 Remove the screws holding the mounting plate on the bottom of the unit 1 2 Remove the mounting plate 3 Align the Universal Din...

Page 10: ...uit is run into the box 1 Switch the circuit breaker to the circuit that the SEM VT01 is being added to 2 Using diagram to the right make high voltage connections 3 Screw the SEM VT01 into the electri...

Page 11: ...e proper polarity install the 20 and 50A current transformers with arrows pointing in the direction of current flow towards the load C Route the wire through a cable clamp on the side of the panel and...

Page 12: ...ct the Energy Monitor and drag into a Global Zone 4 Name the device 5 Place the Energy Monitor in the Layout window 6 Select the Energy Monitor 7 Open Inspector 8 Enter UID Components All Control Type...

Page 13: ...s Energy Monitor 2 Click the Add for SEM2015 Add for SEM1024 2 3 3 Select the Energy Monitor to be used 4 Double click on the Circuit Description Enabled Circuit Description Classification Group Image...

Page 14: ...n Group Image Monitoring Device Channel Size Voltage Source Parent Circuit Control Savant Zone Group Image Production Type Main Power None Feed SEM2015 1 None Choose Utiliy Ro Phase 1 Channel 250 A Vo...

Page 15: ...e house From an open Blueprint configuration do the following 1 Go to Tools Settings Energy Monitor 2 Click the Add for SEM2015 Add for SEM1024 2 3 3 Select the Energy Monitor to be used 4 Double clic...

Page 16: ...n Family Room Room SEM2015 10 None Choose Family R Phase 1 Channel Consumption 9 Phase 2 Channel Consumption Only Main Feed Key Loads This example shows the main power feed and key loads being monitor...

Page 17: ...Consumption Consumption Production Family Room Room SEM2015 10 None Choose Family R Phase 1 Channel Consumption 9 Phase 2 Channel Solar Auxiliary Generator The example below shows a completed configu...

Page 18: ...Phase 1 Channel Dishwasher Appliances SEM2015 01 6 None Choose Kitchen Phase 1 Channel A C hvac SEM2015 01 7 None Choose Utiliy Ro Phase 1 Channel Work Shop None SEM2015 02 1 None Choose Work Sh Phase...

Page 19: ...he Current rating of the current transformer 7 Select the circuits Classification 8 Repeat steps 4 though 7 for each current transformer is use 9 Click Deploy Config HELPFUL INFO Inv This column stand...

Page 20: ...al Voltage sensor for use in conjunction with Savant Energy Monitors SEM 020A5 SEM 020A5 is a 5 pack of 20 Amp split core clip on current transformers SEM 050A5 SEM 050A5 is a 5 pack of 50 Amp split c...

Page 21: ...tems Inc 009 1928 01 200828 21 of 24 SKU Description Image SEM 250A1 SEM 250A1 is a 250 Amp split core clip on current transformer SEM 400A1 SEM 400A1 is a 400 Amp split core clip on current transform...

Page 22: ...he end user accesses their monitoring info within the Savant UI Select a predefined group same list or select the text field to enter a custom group name Configured groups form the top level navigatio...

Page 23: ...fication Options include Generator Solar or Battery Clicking this box will do the following If a circuit level row is selected or there is no selection a new circuit will be added If a phase channel i...

Page 24: ...l rights reserved Savant Savant App TrueImage Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems Inc AirPlay Apple...

Reviews: