Savant IP Audio 1 Deployment Manual Download Page 22

Savant IP Audio Deployment Guide

Copyright © 2020 Savant Systems, LLC

009-1571-03  |  200224

22     of     39

6.2.  Status Tab

This tab is available on all IP Audio devices.

10.0.100.50

Status

Network

Inputs & Outputs

Status

Savant ID

IP Address

Firmware Version

Uptime

001AAE0000000000

10.0.100.50
9.1:62

0 days 2 hours 53 minutes

Restart

IP Audio 1, PAV-SIPA1SM

A

B

C

D

E

A

Savant ID

UID of the device.

B

IP Address

Currently assigned IP Address.

C

Firmware Version

Current Firmware Version number.

D

Uptime

Amount of time the unit has been powered without 

a restart.

E

Restart

Restarts the software of the unit.

6.3.  Network Tab

This tab is available on all IP Audio devices.

10.0.100.50

IP Audio 1, PAV-SIPA1SM

Status

Network

Inputs & Outputs

Network

DHCP

IP Address

Subnet Mask

Router

10.0.100.1

Apply & Restart

Static

255.255.255.0

10.0.100.50

Revert

A

B

C
D

E

F

A

IP Address 

Configuration

DHCP (Dynamic Host Configuration Protocol) or 

Static.

B

IP Address

Displays the current IP Address and allows for entry. 

This is automatically assigned when item A is set to 

DHCP.

C

Subnet Mask

Subnet mask of the network. This is automatically 

assigned when item A is set to DHCP.

D

Router

IP Address of the network router. This is also known 

as Gateway or Default Gateway.

E

Revert

Select to erase entered settings and revert back to 

saved settings.

F

Apply & Restart

Select to apply entered settings, and restart the 

device.

 

NOTES

:

 

Setting the IP Address with a Static Address from the WebUI will automatically set the devices DNS to 8.8.8.8 and 8.8.4.4 (Google).

 

A second method for setting these devices to a Static IP can be done with EMBScanner, for information on this method see Appendix B for 

more information.

Summary of Contents for IP Audio 1

Page 1: ...Blueprint configuration and web based user interface setup Products supported by this guide include IP Audio 1 with Savant Music 2 0 PAV SIPA1SM IP Audio 50 with Savant Music 2 0 PAV SIPA50SM IP Audio...

Page 2: ...undbar 15 5 Blueprint Configuration 17 5 1 Basic Blueprint Layout 17 5 2 Adding a Savant IP Audio Device to a Configuration 17 5 3 Assigning Inputs and Outputs I Os 18 5 4 AVB Speaker Grouping 19 6 We...

Page 3: ...uch attachments accessories 12 Disconnect any outlet powered apparatus from its power source during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service...

Page 4: ...Device firmware updates require a valid Internet connection to be downloaded to the Host Supported Release Device Minimum Supported Release PAV AIM7C xx da Vinci 8 7 PAV AOM8C xx da Vinci 8 7 PAV AOM...

Page 5: ...re determined by the logical connection within Blueprint 3 1 Network Connection Savant IP Audio devices use a standard RJ 45 port complying with IEEE 802 3 Ethernet standards This port also supports A...

Page 6: ...the unit slowly As the cartridge is removed make note of the orientation as it is important to proper operation TIP Mark the chassis and fuse holder with a marker in order to align when replacing 4 Re...

Page 7: ...nnections to component devices IMPORTANT IR Wiring Precautions Ensure that all IR emitters are within 15 feet 4 6 meters of the controller s location Use of 3rd party flashing IR emitters with Talk Ba...

Page 8: ...ing is supported for flow control based on the profile used in the configuration IP Audio devices do not support RS 422 485 RJ 45 to DB9 Serial Control Adapters Refer to the RS 232 Conversion to DB9 a...

Page 9: ...a 1K ohm pull down resistor to signal ground which keeps the GPIO output below 0 8V during processor boot times HELPFUL INFO GPIO functionality for Savant Controllers is defined by the associated Pro...

Page 10: ...tional rack bracket 4 1 PAV SIPA50SM Rack Installation The PAV SIPA50SM can be mounted in a 2U rack style enclosure and is compatible with all standard 19 inch NEMA rack mounts The rack bracket needs...

Page 11: ...ck mounts The rack brackets need to be attached prior to placing in a rack 4 3 PAV SIPA1SM The PAV SIPA1SM includes side mounting brackets for installation in a structured media panel enclosure or on...

Page 12: ...PAV AOMBAL8C These devices can be placed on a solid flat surface such as a table or shelf Or these devices can use the optional RMB PAVAM2F xx or RMB PAVAM2 xx allows two devices to be mounted side by...

Page 13: ...Mount Kit Requires the Micro Aperture 4 Pre Construction Bracket 1 Before drywall install the mud housing to the pre construction bracket using the spacers x4 and long 20 mm screws x4 See Notes x4 x4...

Page 14: ...Aperture 4 speaker IMPORTANT The AVB speaker must be the first Left channel The AVB speaker can also drive up to two right channels and one additional left channel 1 Use the cutout template to cut a h...

Page 15: ...unt depth 0 9 1 2 in C Shape None 1 1 in 1 8 2 8 in C Shape 50 mm 1 1 in 2 7 3 6 in C Shape 70 mm 1 1 in 2 1 2 5 in L Shape None None 3 0 4 0 in L Shape 50 mm None 3 8 4 7 in L Shape 70 mm None Bracke...

Page 16: ...enough to mount the stabilizer foot preferably close to the edge of the TV 2 Clean the intended attachment area on the TV chassis with an alcohol wipe to remove any latent grease 3 To install the Sli...

Page 17: ...on in Blueprint for a single unit deployment Making an AVB connection in Blueprint when it is not going to be used may cause some stability issues The IP Audio devices allows multiple units to functio...

Page 18: ...on Support for Multiple Audio Outputs Active Simultaneously in a Zone available on the Savant Customer Community Connectors AVB_A Ethernet port AVB A Digital Audio In 1 Digital Op Digital Audio In 2 D...

Page 19: ...Savant Host SIPA125SM IR Serial PWM Output 1 Control Ports Digital Audio In 1 Digital Optical Audio Input 3 Assigned Inputs AVB_A Ethernet Port AVB A Data GPIO 1 Audio Output 5 Assigned Outputs Stereo...

Page 20: ...al Optical DIGITAL AUDIO OUT Resource Audio Cable TV TV Source SIPA125SM Audio Switch Function Stereo Audio Processor Function Volume Control Function Sub Amplifier Function Stereo Speakers Sink SIPA1...

Page 21: ...m Monitor rpmEmpScanner or any network scanning software 1 On the SDE open a Web Browser and enter the address of the device in the address bar Syntax http IP Address of Device 10 0 100 50 Favorites i...

Page 22: ...Address Subnet Mask Router 10 0 100 1 Apply Restart Static 255 255 255 0 10 0 100 50 Revert A B C D E F A IP Address Configuration DHCP Dynamic Host Configuration Protocol or Static B IP Address Disp...

Page 23: ...the input and output To connect an input to an output manually from the WebUI click and drag to draw the connection from the black dot on the input to the black dot on the output NOTE Audio paths tha...

Page 24: ...p To permanently adjust trim settings apply the changes in System Monitor C Input List List of the inputs on the device D I O Connection Indicator Active connections are represented by a black line be...

Page 25: ...dicator Active connections are represented by a black line between the input and output To connect an input to an output manually from the WebUI click and drag to draw the connection from the black do...

Page 26: ...ented by a black line between the input and output To connect an input to an output manually from the WebUI click and drag to draw the connection between the black dot on the input to the black dot on...

Page 27: ...Mono by clicking in this field Mono Summing combines the left and right input signal into a single speaker channel output C Process This cannot be changed on the IP Audio Micro Aperture speakers D Del...

Page 28: ...Host uploads E Test Tone Toggles a constant 1kHz tone through all un muted channels PAV SIPA125SM 10 0 100 50 IP Audio 125 PAV SIPA125 Status Network Inputs Outputs Calibration Calibration HPF Cutoff...

Page 29: ...ected to one of the AVB_B Ethernet Ports on the switch The AVB Switch Uplink Port must be connected physically to the regular networking switch on site however this connection is assumed and not repre...

Page 30: ...Networks X440 G2 12T ESN AVB12E4SFP Extrem Extreme Networks X440 G2 24T ESN AVB24E4SFP Extrem Generic AVB NetworkSwitch MOTU AVB Switch 3 Drag the switch into a Shared Equipment zone 4 Name the Devic...

Page 31: ..._A Ethernet Port AVB A Assigned Inputs Assigned Outputs SIPA50SM_01 Control Ports Data AVB_A Ethernet Port AVB A Assigned Inputs Assigned Outputs AVB_02 Assigned Data Port 1 AVB_B Ethernet Port AVB B...

Page 32: ...AVB Info tab within System Monitor will display all active connections sending traffic across the AVB network Connections that output from the same device they originate from are not displayed for ex...

Page 33: ...0 Restore Defaults GENERAL System Dashboard Controller Info Processes Diagnostic Reports System Licenses Configuration Info Host Claiming CONTROL System State Service Events Services Component Status...

Page 34: ...io Settings Trim 0 Restore Defaults Volume 17 Min db Max db 60 0 GENERAL System Dashboard Controller Info Processes Diagnostic Reports System Licenses Configuration Info Host Claiming CONTROL System S...

Page 35: ...Savant_music Mainboard Media Source 1 Savant Music Current Audio Format No Info Audio Settings Music Trim dB 0 GENERAL CONTROL System Dashboard Controller Info Processes Diagnostic Reports System Lic...

Page 36: ...IP Address will not change due to a power outage a static IP Address or DHCP reservation should be configured Savant recommends using DHCP reservation within the router By using this method IP Addres...

Page 37: ...inal window on a MacBook SDE 2 Enter ssh RPM IP Address of IP Audio device Example ssh RPM 10 0 100 50 3 When prompted enter the password Default RPM 4 Once logged in the commands below will add remov...

Page 38: ...plementation so that the integrator understands how the system will respond during shutdown and start up periods Power consumption monitoring It is nice to have the ability to monitor the draw from ea...

Page 39: ...reserved Savant Savant App TrueImage Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems LLC AirPlay Apple AirPort...

Reviews: