9
009-1593-02
Network and Configuration Requirements
Network Configuration
Additional Information
Smart Sensor Connection
A 1-wire humidity/temperature (CLI-THFM1) sensor that sup-
ports measuring both humidity and temperature can also be
added to the system. Connect the sensor to the 1-Wire, 5V DC,
and GND terminals as shown in diagram below.
With the thermostat installed and wired, it can now be added
to the local network and once communicating with the Savant
Pro System Host an HVAC configuration can be created and
uploaded to the Host. Locate the
CLI-W200 Thermostat De-
ployment Guide
available on the
Savant Customer Communi-
ty
to finish installation of the thermostat.
To ensure the IP Address will not change due to a power
outage, Savant recommends DHCP reservation be configured.
Using this method, static IP Addresses for all devices can be
managed from a single User Interface, avoiding the need to
access devices individually.
Setting DHCP reservation varies from router to router. Refer
to the documentation for the router to configure DHCP
reservation.
– CLI-W200 Thermostat Deployment Guide (009-1636)
– SST-TEMP1 Remote Indoor Temp Sensor QRG (009-0800)
– SST-OTEMP Remote Outdoor Temp Sensor QRG (009-0989)
– CLI-THFM1-xx Temp and Humidity Sensor QRG (009-1064)
– CLI-SLAB1 Slab Sensor QRG (009-1097)
– CLI-PLEN1R Residential Plenum Sensor (009-1096)
– CLI-PLEN1C Commercial Plenum Sensor (009-1100)
AUX
OUT
AUX
IN
RS2
RS1
GND
GND
RX-
RX+
GND
1-
WIRE
5V
DC
Remote 1-Wire
Sensor