Version 1.0
[
108
]
SAV 876.17
9 APPENDIX
The maximum ambient temperature must not exceed 40 °C at a relative humidity of 50%. Local hotspots must be
excluded.
The ambient temperature must be checked with production conditions during commissioning. If necessary, the
control cabinet has to be equipped with forced cooling or air conditioning.
NOTE!
When connecting the control unit, please observe the separate operating
instructions for the magnet clamping plates and, if applicable, slip ring
bodies and carbon brush holders (for round magnets).
The control unit is designed for the following application and ambient conditions:
Place of use
Installation in a control cabinet
Protection rating of the device
IP20
Level of soiling
2
Max. rel. humidity during operation
50%
Ambient temperature at place of use
0…40°C
Ambient temperature during storage
-20 °C to +70 °C at max. 90% humidity,
non-condensing
Dry and wet processing
Not relevant for the control unit
Altitude during operation
Max. 2000 m a.s.l.