40
4000122704-1
Note: Isolating cocks water and gas are shown in the: OFF position
20 Replacement of Parts
IMPORTANT INFORMATION
WARNING: Before commencing the replacement of any
component, isolate appliance from electrical supply and turn off
gas at service cock.
Replacement of parts must be carried out by a competent
person.
When replacing components it may be necessary to renew
sealing washers, gaskets and 'O' rings. If new ones are
supplied with replacement components they must be used.
All parts are replaced in reverse order to removal.
If any gas-carrying components are disturbed, removed or
replaced it will be necessary on completion to check for gas
soundness with leak detection fluid.
20.1 Central heating thermistor
Before starting refer to the front of Section 20 Important
information.
• Remove the front panel, refer to Section 17.3.
• Lower the control panel, refer to Section 17.4.
• Locate central heating thermistor on heating flow pipe on
centre of boiler, see diagram 20.2.
Diagram 20.2
9550
CENTRAL HEATING
THERMISTOR
Diagram 20.1
9743
To Drain the central heating circuit
• Open drain valve fitted at the lowest point in the system.
• Allow air into the system by opening a radiator bleed screw or the boilers drain
valve (a).
(F30E Only) To Drain the Domestic hot water circuit
• Close boiler isolating valve (c).
• Turn on one or more hot water taps.
To Drain the boiler
• Close isolating screws on the isolating valves (b), (c) and (d) turn from vertical
to horizontal to close.
• Open the boiler drain valve (a).
• (F30E Only) Turn on one or more hot water taps.
(a)
(b)
(c)
(d)
HEATING
RETURN
COLD WATER
IN (F30E SB)
HEATING
FLOW
BOILER DRAIN VALVE
• Unclip thermistor from pipe.
• Disconnect electrical connections from thermistor.
• Fit electrical connections to replacement thermistor and fit
thermistor to pipe. The polarity is not important.
9744
F30E shown
F30E shown
➜
DOMESTIC HOT
WATER OUT
(F30E Only)
➜
GAS SERVICE
COCK