![Saunier Duval Themaclassic F30E PLUS Instructions For Use Installation And Servicing Download Page 28](http://html1.mh-extra.com/html/saunier-duval/themaclassic-f30e-plus/themaclassic-f30e-plus_instructions-for-use-installation-and-servicing_1202909028.webp)
28
4000122704-1
17 Routine Cleaning and Inspection
Diagram 17.3
9533
Diagram 17.4
9533
Note: Isolating cocks water and gas are shown in the: OFF position
Diagram 17.2
9743
To Drain the Domestic hot water circuit (F30E Only)
• Close boiler isolating valve (c).
• Turn on one or more hot water taps.
To Drain the boiler
• Close isolating screws on the isolating valves (b), (c) and (d) turn from vertical
to horizontal to close.
• Open the boiler drain valve (a).
• (F30E Only) Turn on one or more hot water taps.
(a)
(b)
(c)
(d)
HEATING
RETURN
COLD WATER
IN (F30E Only)
HEATING
FLOW
BOILER DRAIN VALVE
9744
F30E shown
F30E shown
➜
DOMESTIC HOT
WATER OUT
(F30E Only)
➜
GAS SERVICE
COCK