BOILER LOCATION
Ven 060a
N
C
D
M
O
P
A
B
E
F
G
I
H
L
Diagram. 26
A -
under a window ........................................................................................ 600
B -
under an air vent ....................................................................................... 600
C -
under a gutter ............................................................................................ 300
D -
under a balcony ........................................................................................ 300
E
-
from an adjacent window ....................................................................... 400
F
-
from an adjacent air vent ........................................................................ 600
G -
from vertical or horizontal air pipes ........................................................... 600
H -
from an external corner of the building ................................................. 300
I
-
from an internal corner of the building ................................................. 1000
L
-
from the ground or from another floor ....................................................... 1800
M -
between two terminals vertically ......................................................... 1500
N -
between two terminals horizontally ...................................................... 1000
Minimum dimensions (in mm) for the positioning of flue terminals