11
DIMENSIONS
OPENING THE CONTROL PANEL COVER
Hab 129
Hab 132
THELIA 23, THELIA 23 E
Net weight
: 41 kg
Gross weight
: 43 kg
THELIA SB 23
Net weight
: 40 kg
Gross weight
: 42 kg
The boiler is delivered in three separate packages :
- the boiler itself
- its connection plate
- the flue system.
Diagram. 20
378
410
857
234
623
802
TECHNICAL DATA
Burner pressure (mbar)
Pom 023
Diagram. 19
Pump
The performance of the pump, running
at maximum speed, varies according to
the pump bypass setting, see diagram
19
.
5
4
3
2
1
0
500
1000
Water flowrate (l/h)
by pass fully closed
by pass fully open
open 1 tur
n
open 3 turns
open 2 tur
ns
Pressure loss between flow and
retur
n boiler connections (metres head)
Heat output
(kW)
8,9
10
11
12
13
14
15
16
17
18
19
20
21
22
23,3
(Btu/h) 30387 34142 37557 40971 44385 47799 51214 54628 58042 61456 64871 68285 71699 75113 79552
Heat input
(kW)
11,9
13,1
14,2
15,3
16,4
17,5
18,7
19,9
21,1
22,2
23,4
24,6
25,6
26,8
28,3
(Btu/h) 40678 44631 48410 52326 56042 59742 63794 67819 71897 75872 79910 83836 87545 91412 96602
GAS
G 20
(mbar)
1,8
2,2
2,6
3,1
3,5
4,0
4,5
5,1
5,8
6,4
7,1
7,8
8,5
9,3
10,4
G 30
(mbar)
4,1
5,0
5,9
6,8
7,8
8,9
10,2
11,5
12,9
14,4
15,9
17,5
19,1
20,9
23,3
G 31
(mbar)
5,3
6,4
7,5
8,7
10,0
11,4
13,0
14,7
16,5
18,4
20,4
22,4
24,5
26,7
29,8
G 130
(mbar)
0,5
0,6
0,7
0,8
0,9
1,0
1,2
1,3
1,5
1,7
1,8
2,0
2,2
2,4
2,7