16
221873B
8 Mounting the boiler
7011
Diagram 8.2
COMBUSTION
CHAMBER PANEL
RETAINING
LUG (4)
6984
Diagram 8.3
AIR
PRESSURE
TUBE (3)
ELECTRICAL
CONNECTIONS
RETAINING LIP
AT REAR
Pull
Forward
FAN
TRANSIT
SCREW (2)
RED
CLEAR
8.1 Boiler Mounting
Remove the inner case front, secured by two clamps at the
bottom lift up and unhook from the threaded lugs at the top, see
diagram 8.1.
Remove the combustion chamber panel transit screws, see
diagram 8.2. (It will not be necessary to refit these).
Slide the combustion chamber panel upwards to disengage
from the retaining lugs, pull forward to remove, see diagram
8.2.
Remove the fan electrical connections by pulling the plastic
boots not the wires. Remove the tubes from fan, noting the
colour tubes positions. see diagram 8.3.
Remove the fan and flue collector assembly by pulling it forward
see, diagram 8.3.
Remove the rear outlet restrictor plate and retain if using the
rear flue outlet, see diagram 8.4.
REAR FLUE ONLY Fit the flue spigot supplied seperately, see
diagram 8.5.
TOP FLUE ONLY Remove the blanking plate from the top of
the boiler and use to blank the hole where the rear restrictor
plate (discard) was fitted.
Note: Should the side clearances be less than 30mm. It will be
necessary to fit the side panels before mounting the boiler.
Refer to Section 10.10 for fitting.
Remove the protective caps from the boiler water pipes.
Fit the sealing washers (supplied in the fittings pack) to the
boiler water pipes by inserting them into the tubing nuts (the
nipples on the washers will hold them in position), see diagram
8.8.
Lift the boiler into position on the top mounting brackets use
hand holes provided, see diagram 8.6.
Diagram 8.1
6965
INNER CASE
FRONT
SECURING
CLAMP (2)
THREADED
LUG (2)