9
INSTALLATION OF THE GENERATOR AND OPTIONAL EXTRAS
Control module
may be installed inside the steam room. If the control module is fitted outside the
steam room or so low within the steam room that its own thermostat does not show the correct
temperature, a separate thermostat which is connected directly to the circuit board must be used. It
must be mounted at a height of 170cm from floor level and preferably opposite the door
(see illustration).
When the
push button
is used, the provided limiting thermostat must
always
be installed, to ensure
the temperature does not rise above +50 °C. See the separate installation and connection diagrams.
Steam nozzle(s)
must be fitted approx. 20 - 40 cm from the floor either under the seat or on the
wall in a position such that hot steam cannot burn the feet. When fitting nozzles, one must also
ensure that they cannot be inadvertently touched.
The temperature of the steam is +100
°C
and it
can cause burns.
The
thermostat
is fitted at a height of 170 cm from floor level and preferably on the wall opposite
the door.
The hole for the thermostat should be sealed with silicone or similar to prevent moisture ingress to
the wall. The thermostat is connected directly to the circuit card of the generator.
(see connection diagram.)
Water
connection
400V 3N~
Floor drain
Temperature sensor
Control module
Steam nozzle
O K
ON OFF
O K
ON OFF
Pressure button