![Saunatec HELO HSS M 34 User And Installation Manual Download Page 3](http://html1.mh-extra.com/html/saunatec/helo-hss-m-34/helo-hss-m-34_user-and-installation-manual_1202830003.webp)
3
INSTALLATION AND USE
HSS M and HST M generators are designed solely for application in steam bathing facilities. Use of
the steam generator for any other purpose is not permitted.
The manufacturer is not responsible for damage caused by equipment that has been incorrectly
installed or used or any consequential loss that may occur.
Prior to electrical connection, plumbing of pipes for water feed and steam delivery must be
completed. All joints should be properly connected and sealed using PTFE thread tape in screwed
connectors. Welding of joints is, however, recommended.
The area where the generator is installed must be dry and well ventilated to dissipate local heat from
the components – note rating is IP 20. Recommended distance from structures above and to the
sides is no less than 30 cm. Consider the space needed around the generator for routine
maintenance. For the emptying of the tank there should be drainage available in the vicinity of the
equipment.
The generator can be wall mounted in which case screws and mounting methods must be
appropriate to the wall material. The generator weights when filled with water are:
HSS, 13 kg and HST, 17 kg (approx.).
When using the automatic flushing valve, ensure that flush pipe is directed towards the drain.
HSS M and HST M generator installation
The control module can be fitted either inside or outside the steam room. When fitted outside the
steam room, a separate thermostat, which is connected to the circuit board, must
always
be used.
Water connector
400V 3N~
Flush
Control module
Steam nozzle
OK
O N O FF
OK
O N O FF
Push
button
Placement of control panel and pressure button Steam generator´s wall mounting holes 3 pcs
Temperature sonsor