INSTALLATION OF THE CONTROL MODULE, PUSH BUTTON AND THE THERMOSTAT:

180 mm

55 mm

150 mm

Distance
between
holes

5 mm

Locking

Affixing hole

40 mm

32 mm

46 mm

Wall

Thermostat
cover

Back nut

Locking screw

21 mm

32 mm

Thermostat

24 mm

24 mm

Back nut

ON - OFF switch

Led-light

The control module is factory sealed to
withstand use in the humidity of the steam 
room. It can be installed directly against
the wall, fixed with suitable screws through
the two fixing holes and sealed in place
with silicone sealed. A hole should be drilled 
in the wall to feed the control cable back to
the generator - this may be directly behind
the control or just below. This hole should
be silicone sealed against ingress of
moisture.
The decorative bezel in Chrome onr White
is designed to clip fit onto the control
housing. This bezel is removed with the
supplied tool. Using this tool lightly press
the locking pin in each of the 4 holes
around the perimeter whilst pulling the 
frame away from the control body. 

The push button has been factory 
sealed to wisthstand the humidity of the 
steam room. Dependent on the type of
wall the button is fitted by drilling a
suitable hole and either securing with
the back nut (acrylis walls) or setting into
position with silicone sealant (solid walls).
If necessary a surface mount box may
be used.
 

The thermostat should be fitted 170 cm above
floor level, ideally on the wall opposite the
door. Drill a suitable hole and secure thermostat
either with the locknut (acrylic walls) or by 
setting in place with silicone sealant (solid walls)
Ensure that a good tight seal is made to avoid 
ingress of moisture to the wall. The thermostat
is inserted into its decorative casing.
.

Locking

Locking

Locking

Summary of Contents for HELO HSS M 34

Page 1: ...1 SAUNATEC GROUP Ltd HELO HSS M and HST M STEAM GENERATOR User and Installation Guide for models HELO HSS M 34 47 60 77 HELO HST M 90 120 140 314 SHS 64 C...

Page 2: ...gramme Automatic fill and water level setting Floor or wall mounting Digital control module Temperature control Time control Light control Control module may be fitted on inside or outside of steam ro...

Page 3: ...ures above and to the sides is no less than 30 cm Consider the space needed around the generator for routine maintenance For the emptying of the tank there should be drainage available in the vicinity...

Page 4: ...pe MUST NOT include traps as the water which collects will cause restricted steam flow and spitting at the steam head Any water from condensation in the pipe must be allowed to flow freely back into t...

Page 5: ...oning and good ventilation may also need more power The required power can be estimated using the following formula Capacity m3 x K1 x K2 Required power kW Ventilation K1 0 75 No ventilation K1 0 52 A...

Page 6: ...1 N 3 N N N N N V2 V1 H1 H2 N L PE OLEA 72 S1 S2 High level Water valve drain 230 V AC Water valve filling 230 V AC Heater fuse Elements Contactor LC1 LC2 B1 B2 T1 T2 A K S1 S2 TX RX 5 0 Serial traffi...

Page 7: ...5 0 354 SHS 33 A 1 5 2 6 Level probe Earthing for cover High level Water valve drain 230 V AC Water valve filling 230 V AC Heater fuse Elements Contactor Serial traffic to MIDI control On Off Push but...

Page 8: ...230 V AC Water valve filling 230 V AC Thermofuse Contactor LC1 LC2 B1 B2 T1 T2 A K S1 S2 TX RX 5 0 Control keyboard On Off pushbutton Thermostat Alarm 12 V DC Light control opto max 24 V DC 50 mA 1 6...

Page 9: ...the separate installation and connection diagrams Steam nozzle s must be fitted approx 20 40 cm from the floor either under the seat or on the wall in a position such that hot steam cannot burn the fe...

Page 10: ...ashing Bathing time selection button time display flashing plus button for increasing the setting of time and temperature minus button for decreasing the setting of time and temperature Light control...

Page 11: ...ed to LC1 When the lights button is pressed a transistor on the circuit board transfers the voltage into LC2 which carries out the actual light unit control PUSH BUTTON Functions of the button When st...

Page 12: ...ite is designed to clip fit onto the control housing This bezel is removed with the supplied tool Using this tool lightly press the locking pin in each of the 4 holes around the perimeter whilst pulli...

Page 13: ...he flush and rinse After the cycle has run the generator will await a new start up command ELECTRIC FLUSHING VENT Drain Kit M Optional extra HSS M and HST M generators flushing vent installation Use P...

Page 14: ...removal of lime from the tank Testing water quality and de scaling for HSS M and HST M generators Test strips included in the test pack supplied with the generator are used as follows Submerge the tes...

Page 15: ...n fitted with an automatic or a manual flushing valve Automatic flushing valve The generator will empty and rinse itself after 15 minutes of idle time After the first flush generator is started again...

Reviews: