Quick Start Guide

Air velocity and temperature
transmitter

General features

Features of the housing

Used symbols

For your safety and in order to avoid any damage of the device, please follow the procedure described in 
this document and read carefully the notes preceded by the following symbol: 
 
The following symbol will also be used in this document, please read carefully the information notes 
indicated after this symbol: 

CTV 210-R

Connections

Electrical connections as per NFC15-100 standard

All dimensions are in millimeters.

-

+

24 Vdc

Power supply

N-

L+

N

L

24 Vac power supply

class II EN61558-2-6 standard

N-

L+

Pe
N
L

or

N

L

Power supply

N-

L+

Pe

N

L

230 Vac

230 Vac

N

L

100-240 Vac

Power supply

N-

L+

This connection must be made by a formed and qualified technician. To make the connection, the transmitter must not 
be energized. Before making the connection, you must first check the power supply indicated on the transmitter board 
(see (b) on “Connections” part). The presence of a switch and a circuit breaker upstream the device is compulsory.

On 100-240 Vac models, if a fuse protection is used for the power line, it is imperative to use delayed-action 
fuses in order to absorb the surge of current when first turned on the transmitter.

The selection of the output signal in voltage (0-10 V or 0-5 V) or in current 
(4-20 mA or 0-20 mA) is made via the DIP switch (d) of the electronic board 
of the transmitter: put the on-of switches as shown in the table below: 

Configurations

4-20 mA

0-10 V

0-5 V

0-20 mA

Combinations

1   2   3   4

1   2   3   4

1   2   3   4

1   2   3   4

• 

Connection of the output in current 

4-20 mA: 

• 

Connection of output in voltage 

0-10 V: 

• 

For transmitters with 24 Vdc power supply: 

• 

For transmitters with 24 Vac power supply: 

• 

For transmitters with 100-240 Vac power supply:

-

+

0-5/10 V

0/4-20 mA

Regulator display or

PLC/BMS 

passive type

A

4-20 mA output

-

+

0-5/10 V

0/4-20 mA

Regulator display or

PLC/BMS 

passive type

V

0-10 V output

Two 4-wire analogue output 
0-5/10 V or 0/4-20 mA

Airflow function

ABS V0 IP65 housing, 
optional display

2 relay outputs

0-5 / 10 V 

4-20 mA

Power supply

24 Vac / Vdc ±10%. 100-240 Vac, 50-60 Hz

Warning: risk of electric shock 

Output

2 x 4-20 mA or 2 x 0-20 mA or 2 x 0-5 V or 2 x 0-10 V (4 wires)

Common mode voltage <30 Vac. Maximum load: 500 Ohms (0/4-20 mA). Minimum load: 1 K Ohms (0-5/10 V)

Relay outputs

2 changeover relays 3 A / 230 V. NO : 5A / NC: 3A / 240 Vac

Galvanic isolation

Inputs and outputs (models 100-240 Vac). Device fully protected by 

DOUBLE ISOLATION or REINFORCED ISOLATION

Outputs (models 24 Vac/Vdc)

Consumption

CTV210-B: 6 VA. CTV210-H: 8 VA

Electrical connection

Screw terminal block for cable 2.5 mm². Carried out according to the code of good practice

PC communication

USB-Mini Din cable

Environment

Air and neutral gases

Conditions of use (°C/%RH/m)

From -10 to +50 °C. In non-condensing condition. From 0 to 2000 m.

Storage temperature

From -10 to +70 °C

Security

Protection class II; Pollution degree 2; Overvoltage category 2 (OVCII)

European directives

2014/30/EU EMC; 2014/35/EU Low Voltage; 2011/65/EU RoHS II; 2012/19/EU WEEE

Material

ABS V0 as per UL94

Protection

IP65

Display

75 x 40 mm, LCD 20 digits 2 lines.

Height of digits: Values: 10 mm; 

Units: 5 mm

Cable gland

For cables Ø 8 mm maximum

Weight

340 g

1

1

5

125

59

             CTV210-XXX-S-R
Power supply: 

100-240 Vac

                          50-60 Hz 8 VA

Output: 

0/4...20 mA / 0...5/10 V

100-240 Vac

24 Vac/Vdc

             CTV210-XXX-S-R
Power supply:

 24 Vac/Vdc ±10 %

                          50-60 Hz 6 VA

Output:

 0/4...20 mA / 0...5/10 V

Power supply type (b) specified on the label
on the side of the transmitter

1

2

3

4

5

7

6

Analogue output 1

(out 1)

0-5/10 V 

– V

oltage 

GND – Ground 

0/4-20 mA – Current

Analogue output 2

(out 2)

0-5/10 V 

– V

oltage 

GND – Ground 

0/4-20 mA – Current

(a)

(c)

or

For 

24 Vdc 

power

supply models

-

+

(c)

or

For 

24 Vac 

power

supply models

Neutral (N)~
Phase (L)~

(c)

For 

100-240 Vac

power supply models

Neutral (N)~
Phase (L)~

Relays 1 and 2

COM: common

NC: normaly closed

NO: normaly opened

Operating grounding

*Fuse present only for 100-240 Vac models.
Every fuse replacement must be performed witht a power off device using a TR5 630 mA 250 V fuse.

2

1.  DIP switch (d)
2.  LCC-S software connection
3.  Relays
4.  Analogue outputs (a)
5.  F3.20* fuse
6.  Power supply terminal block (c)
7.  Cable glands

Summary of Contents for CTV 210-R

Page 1: ...CTV 210 R Quick Start Guide www sauermanngroup com EN FR ES ...

Page 2: ...Airflow function ABS V0 IP65 housing optional display 2 relay outputs 0 5 10 V 4 20 mA Power supply 24 Vac Vdc 10 100 240 Vac 50 60 Hz Warning risk of electric shock Output 2 x 4 20 mA or 2 x 0 20 mA or 2 x 0 5 V or 2 x 0 10 V 4 wires Common mode voltage 30 Vac Maximum load 500 Ohms 0 4 20 mA Minimum load 1 K Ohms 0 5 10 V Relay outputs 2 changeover relays 3 A 230 V NO 5A NC 3A 240 Vac Galvanic is...

Page 3: ...ntil you hear a click which confirms that the transmitter is correctly installed 0 m s 0 V 4 mA 15 30 m s 10 V 20 mA New range 0 m s 0 V 4 mA 5 30 m s 10 V 20 mA 25 2 Capteur transmetteur de vitesse de l air et température Caractéristiques générales Caractéristiques du boîtier CTV 210 R Les dimensions sont exprimées en millimètres Sortie analogique 4 fils 0 5 10 V ou 0 4 20 mA Fonction débit d air ...

Page 4: ... Vdc CTV210 XXX S R Power supply 24 Vac Vdc 10 50 60 Hz 6 VA Output 0 4 20 mA 0 5 10 V Type d alimentation b précisée sur l étiquette sur le côté du capteur 1 2 3 4 5 7 6 Sortie analogique 1 out 1 0 5 10 V Tension GND Masse 0 4 20 mA Courant Sortie analogique 2 out 2 0 5 10 V Tension GND Masse 0 4 20 mA Courant a c ou Pour les modèles en alimentation 24 Vdc c ou Pour les modèles en alimentation 24...

Page 5: ... 4 20 mA Función de caudal Carcasa de ABS V0 IP65 Pantalla opcional 2 salidas de relé 0 5 10 V 4 20 mA 115 125 59 CTV210 XXX S R Alimentación 100 240 Vac 50 60 Hz 8 VA Salida 0 4 20 mA 0 5 10 V 100 240 Vac 24 Vac Vdc CTV210 XXX S R Alimentación 24 Vac Vdc 10 50 60 Hz 6 VA Salida 0 4 20 mA 0 5 10 V Tipo de alimentación b especificada en la etiqueta lateral del transmisor 1 3 4 5 7 6 Salida analógica...

Page 6: ... Teclado en modelos con pantalla dispone de un código de acceso para asegurar la instalación vea el manual de usuario Programa LCC S opcional en cualquier modelo configuración simple y de fácil manejo Vea el manual del programa LCC S Salidas analógicas configurables Puede configurar rangos de medición con cero central p ej 50 0 50 Pa con cero desplazado p ej 300 0 70 Pa o rango positivo p ej 0 100 P...

Page 7: ...tail service clients Portal de servicio al cliente Portale servizio clienti Use our Customer service portal to contact us Utilisez notre Portail service clients pour nous contacter Contacte con nosotros a través del Portal de servicio al cliente Utilizzate il nostro Portale servizio clienti per contattarci Download the full manual Télécharger le manuel complet Descargue el manual de usuario Scaric...

Reviews: