background image

 

 

Specifications 

Name 

Hot Wire Anemometer 

Model 

SK-28V 

Cat. No. 

No. 7863-01 

Measuring Object 

Clean air in normal pressure 

Measuring Range 

(Dual ranges) 

Air Velocity 

: 0.5 to 3 m/s, 3 to 40 m/s 

Temperature 

: 0 to 60°C, 60 to 120°C 

Static Pressure  : 0 to 500 Pa, 500 to 4500 Pa 

Accuracy 

Air Velocity 

:  ± (5% of FS + 0.1m/s) at 18 to 28°C,   

                                  ± (5% of FS + 0.1m/s + 

δUt (*)) at 0 to 18°C, 28 to 120°C 

Temperature 

:  ± 0.5°C at 0 to 120°C 

Static Pressure  :  ± 2% of FS in 10Pa or higher 

Operating Ambient 

Ambient temperature of instrument 

: 5 to 45°C 

Ambient humidity of instrument 

: less than 85% RH 

Temperature 

Compensation 

0 to 120°C 

Power Requirement 

9.0

VDC: “C” size alkali battery (LR14) 

×

6 pcs. 

Battery Life 

About 20 hours in continuous use at air velocity of 20m/s at 25°C (in use of new 

“C” size batteries) 

Sensor Element 

Specially coated platinum element 

Dimensions 

Probe            : Ø8 to Ø18.7mm

×

(180 to 930mm) (telescoping type)   

Sensor cord : Ø6 × 3,000mm (length changes depending on probe length) 

Main unit      : (W)214

×

(H)117

×

(D)155mm 

Materials 

Body 

: Aluminum 

Sensing stem 

: Brass (BS) w/ chrome plating 

Weight 

about 2.3 kg (including batteries and carrying case) 

Accessories 

Adaptor for static pressure

×

1   

“C” size Alkali battery

×

6   

Carrying case 

×

1   

All specifications and appearances subject to change with or without notice.

 

 

 
*) 

δUt = 0.003 X FS x 

Δ

T(at 0 to 18°C: 

Δ

T=3°C, at 28 to 120°C

:

 

Δ

T=77°C) 

 

  

 

 

No. 3 Nishi-Fukudacho, Kanda, Chiyodaku, Tokyo 101-0037 Japan 

URL: http://www.sksato.co.jp/english/

 

Summary of Contents for SK-28V

Page 1: ...Instruction Manual No 7683 01 Hot Wire Anemometer Model SK 28V L10...

Page 2: ...the SK 28V please contact our retailer or our service network Descriptions Adopting the principle of thermal anemometer this product can measure wide range of air velocity The measured value can be r...

Page 3: ...r Lamp Function Switch Range Selector Zero Adjustment Pivot Pointer Sensor Cap Detection Window with mesh Air velocity Sensor Temperature Sensor Wind Direction Mark Sensor Cord Carrying Case Sensor St...

Page 4: ...pacity 1 Place the Function Switch in BATT position Confirm that the pointer is in the blue zone of the scale plate When the batteries are new the pointer will point to the right end plus side which i...

Page 5: ...ature and static pressure are as follows Select HIGH and LOW depending on the circumstances Range LOW HIGH Air velocity 0 5 to 3 m sec 3 to 40 m sec Temperature 0 to 60 C 60 to 120 C Static pressure 0...

Page 6: ...ng Make sure to face the wind direction mark to the sucker for negative pressure Refer to Fig 1 4 Strongly press the sucker for negative pressure against the measurement hole and take measurement Refe...

Page 7: ...ccuracy of measured value of air velocity will be affected In such a case contact us for cleaning unit on charge bases 4 Never wipe or rub the unit with a dry cloth or like for cleaning Doing so may g...

Page 8: ...ement 9 0VDC C size alkali battery LR14 6 pcs Battery Life About 20 hours in continuous use at air velocity of 20m s at 25 C in use of new C size batteries Sensor Element Specially coated platinum ele...

Reviews: