IntelliFlow 3 Liquid Installation Guide
9
875-3000-100 Rev A1
To install the flow meter and valve/motor:
1. Measure and cut hoses to connect (see warning above):
• Spray valve to the flow meter
• Flow meter to the valve/motor assembly
• Valve/motor assembly to the boom
2. Secure the hoses using two clamps at each connection. This now constitutes the ‘IntelliFlow 3 assembly’.
3. Attach the IntelliFlow 3 assembly to the boom supply plumbing.
4. Install one or two support fittings from supporting structures of the belly skin of the aircraft close to the valve and flow
meter.
Do not connect support fittings directly to the flowmeter or valve/motor. Use stainless wrap-around straps and supports.
Table 4: Minimum Hose Length Between Components
Flow Meter Size Distance Between Spray Valve
and Flow Meter
Distance Between Flow Meter
and Flow Control Motor
3”
10:1 Recommended Min – ≥ 30”
Due to aircraft limitations 18” is acceptable
absolute minimum
6:1 Recommended Min – ≥ 18”
2”
10:1 Recommended Min – ≥ 20”
Due to aircraft limitations 18” is acceptable
absolute minimum
6:1 Recommended Min – ≥ 12”
1.5”
10:1 Recommended Min – ≥ 15”
6:1 Recommended Min – ≥ 9”
1”
10:1 Recommended Min – ≥ 10”
6:1 Recommended Min – ≥ 6”
.5”
10: 1 Recommended Min – ≥ 5”
6:1 Recommended Min – ≥ 3”