IntelliFlow 2 Liquid Installation Guide

5

875-0387-100 Rev A1

051-0404-000

G4 CAN Cable

 

(1) (red cable)

Connects part I’s TERMINAL cable 

to G4’s FLOW port

051-0403-000

Bantam Serial Cable 

(1) (red cable)

Connects part I’s TERMINAL cable  to

Bantam’s FLOW port

054-0101-000

IF2 Power Cable 

(1) (black and white cable)

Connects part I’s POWER cable to 

aircraft power source,  see item K

054-0111-222

IF2 Motor Cable 

(1) (red cable)

Connects part I’s REG VALVE cable to 

valve/motor part B

051-0173-000

Pre-amp Sensor Extension Cable 

(1) (white cable)

Connects  part I’s FLOW METER cable to 

part N

051-0405-000

Trim Pressure Switch Cable 

(1) (red cable)

Connects part I’s TRIM/PRESSURE cable to 

pressure switch part J and optional pressure 

transducer part S

054-0225-000

Main Harness Cable 

(1) (red cable with 10 extensions)

Connects to IF2 controller part O

075-0035-222

Boom Pressure Switch 

(1)

Detects boom pressure

424-0004-222

Power Switch/Circuit Breaker

(1, 10A)

Use with cable  E, wire in with aircraft power

750-0110-03 (1”)

or

750-0109-03 (2”)

or

750-0107-03 (3”)

Aviation Hose 

( 1x19.75 of 1”, 2” or 3”)

Use between spray valve and meter; meter 

and valve; valve and boom. Attach with 

part M.

682-1053-222 (2.25”)

or

682-1054-222 (2.75”)

or

682-1056-222 (3.75”)

Hose Clamp 

(4 of 2.25”, 2.75”, or 3.75”)

Attach to Hose L

121-0004-000

3-Pin Flowmeter Sensor

(1)

Magnetic pick-up sensor to use with 

flow meter part A

800-0004-01

IF2 Controller

(1)

Liquid and Dry Controller

Kit #711-0001-01

Bolt, 1/4” (2)

Washer, 1/4”, locking (2)

Washer, 1/4” plain, flat (4)

Nut, 1/4”, locking (2)

Use items as required for your specific 

installation

Kit #711-0001-01

IF System Control Label

(2)

Use with switch on part F

Kit #711-0001-01

Terminal Ring

(2)

121-0032-01

Pressure Transducer

(Optional, not included in kits)

If used, connect to cable H.  Can set data 

panel or lightbar to display th

pressure 

reading (option is ‘Primary Boom PSI’).

602-1142-000

Legacy IntelliFlow to IntelliFlow2 

Adapter Plate

(1)

*Included in the upgrade kits

Table 3: IntelliFlow 2 Liquid Installation Parts

Summary of Contents for IntelliFlow 2

Page 1: ...This installation guide lists all the parts in the IntelliFlow 2 IF2 liquid kits and provides instructions on how to install the IF2 components associated cables and switches Read this manual thoroug...

Page 2: ...escription maps PMAPs in the GPS system Fine tune applications through the rate bump feature for more precise applications The Satloc G4 will switch between liquid and dry settings with ease Control y...

Page 3: ...instruction For trouble free operation and maintenance of your IF2 system adhere to the following recommendations Avoid using IF2 in extreme environmental conditions 40 140 F is recommended operating...

Page 4: ...750 0046 000 0 5 x1 x1 NPTM 750 0122 000 1 x1 x1 NPTM 750 0091 222 1 5 x2 x 2 Barbed 752 0010 01 1 5 x1 5 x1 5 NPTM 752 0015 01 1 5 x2 x2 NPTM 752 0011 01 2 x2 x2 NPTM 752 0012 01 3 x3 x3 Flange 806 1...

Page 5: ...424 0004 222 Power Switch Circuit Breaker 1 10A Use with cable E wire in with aircraft power 750 0110 03 1 or 750 0109 03 2 or 750 0107 03 3 Aviation Hose 1x19 75 of 1 2 or 3 Use between spray valve...

Page 6: ...using hardware part P Figure 1 Display of How to Connect Cables and Parts for an IntelliFlow 2 Liquid Install Cables and Connections for IF2 Liquid Install New Controller Installation If you are repla...

Page 7: ...ted within easy reach of the pilot Install per pilot s preference 15 Connect part H s BOOM SENSOR cable to part J 16 Connect the single red ignition wire of part I to 24VDC at part K for fused protect...

Page 8: ...d Min 5 6 1 Recommended Min 3 To install the flow meter and valve motor 1 Measure and cut hoses to connect see warning above Spray valve to the flow meter Flow meter to the valve motor assembly Valve...

Reviews: