10
VERSA Plus LTE
SATEL
ETHM LED:
OFF – Ethernet communicator is disabled,
ON – Ethernet communicator is enabled.
SIM LED:
OFF – cellular communicator is disabled,
single flash – cellular communicator is enabled, SIM 1 card is active,
double flash – cellular communicator is enabled, SIM 2 card is active.
RJ-45 connector for Ethernet network. It is provided with two LEDs:
green – ON when the control panel is connected to the network,
yellow – flashes during data transmission.
Description of terminals
AC
- power input (18 VAC).
- protective terminal of telephone communicator (to be connected only to
the PE protective earth circuit of 230 VAC mains).
T-1, R-1
- telephone line output (to premise telephones).
TIP, RING
- telephone line input (from telephone provider).
RNC
- normally closed contact of the programmable relay output (output 5).
RNO
- normally open contact of the programmable relay output (output 5).
RCOM
- common contact of the programmable relay output (output 5).
+OUT1-, +OUT2-
- programmable high-current outputs. +12 VDC voltage is always present
at the “
+
” terminal. The “
–
” terminal is either shorted to or disconnected
from the common ground, depending on the output status
(active/inactive) and polarity.
O3, O4
- programmable low-current outputs, OC type.
COM
- common ground.
AUX
- +12 VDC power output.
KPD
- +12 VDC power output.
DTA
- communication bus data.
CLK
- communication bus clock.
Z1...Z4
- zones.
TMP
- tamper input (NC) – if not used, it should be shorted to the common
ground. The TMP input has number 31 in the system.
S-, S+
- terminals for connecting sounder installed in the enclosure (sounder is
included in the control panel delivery set).
+VR
- ded12 VDC power output for supply of the ABAX 2 (ACU-220 /
ACU-280) / ABAX (ACU-120 / ACU-270 / ACU-100 / ACU-250) /
MICRA (VERSA-MCU) controller.
B 485 A
- terminals intended for future applications (RS-485).
-SPK+
- terminals for connecting the INT-AVT terminal speaker.
-MIC+
- terminals for connecting the INT-AVT terminal microphone.
5.5 Connecting devices to the communication bus
The bus wires must be run in one cable.
The total length of the expander bus may not exceed 600 m.
Summary of Contents for VERSA Plus LTE