SATEL
VERSA Plus LTE
17
Fig. 14. Connecting the INT-IT / INT-IT-2 module to the control panel.
Fig. 15. Setting the address, as in the case of the INT-IT / INT-IT-2 module.
5.6 Connecting the detectors
How the detector is connected to the zone must be suitable for the configuration chosen for
that zone. The zones on the control panel mainboard support the following configurations:
NC
– the wiring type dedicated to connecting devices with the NC (normally closed) alarm
output. Opening the circuit will trigger an alarm.
NO
– the wiring type dedicated to connecting devices with the NO (normally open) alarm
output. Closing the circuit will trigger an alarm.
EOL
– this wiring type may be used to connect devices having the NC or NO alarm output.
Closing or opening the circuit will trigger an alarm.
2EOL/NC
– the wiring type recommended to connect detectors having the NC alarm output
and a tamper output. The zone can recognize 3 states: normal, alarm and tamper.
2EOL/NO
– the wiring type similar as 2EOL/NC, but for detectors with the NO alarm output.
Roller
– the wiring type dedicated to connecting roller shutter detectors.
Vibration
– the wiring type dedicated to connecting shock detectors. The zone will also
accept connection of a detector with the NC alarm output (e.g. a shock detector and
a magnetic contact can be connected in series).