background image

 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

PROGRAMMING 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

perfecta-t_p_en 07/20 

 
 
 

SATEL sp. z o.o. 

ul. Budowlanych 66 

• 80-298 Gdańsk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Al

arm 

Control Pa

nel

 

PERFECT

A

-T

 F

ir

mware

 V

ers

ion

 1.0

4

 

Summary of Contents for PERFECTA-T

Page 1: ...PROGRAMMING perfecta t_p_en 07 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu Alarm Control Panel PERFECTA T Firmware Version 1 04...

Page 2: ...tions and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type...

Page 3: ...than 10 seconds it has no effect on the operation of the 19 Trouble status type output which is activated immediately after AC power is lost Outputs The list of troubles which can trigger the 19 Troub...

Page 4: ...ECTA SOFT program 8 3 1 Description of the PERFECTA SOFT program 8 3 1 1 Menu bar in the PERFECTA SOFT program 8 3 1 2 Side menu 10 3 1 3 Additional menu 10 3 2 Establishing connection between the pro...

Page 5: ...hones 31 10 1 2 AUDIO messaging 32 10 1 3 AUDIO messages 32 11 Timers 33 11 1 Parameters and options of the timers 33 11 1 1 Editing the timer parameters 34 12 Control panel firmware update 34 13 User...

Page 6: ...nu will be displayed the cursor will show the END SM function 2 2 Starting the service mode from pins When entering the service mode in the normal way is not possible the control panel does not suppor...

Page 7: ...n the LIST OF SERVICE FUNCTIONS document 1 Use the number keys to enter the number use the key to erase the last digit 2 The menu item designated by this number will be displayed use the key to go bac...

Page 8: ...can change its status by pressing any number key If you want to restore the previous way of presentation of the list press or 2 5 3 Entering decimal values To enter digits use the number keys Use the...

Page 9: ...ation about the letter case ABC or abc it will be displayed after pressing any key and will be visible for a few seconds after the last keystroke Use the and keys to move the cursor The key deletes th...

Page 10: ...eu website Required program version 1 05 or newer Communication between the program and the control panel is encrypted You can program the control panel from a computer connected to the RS 232 TTL por...

Page 11: ...n full version click to display additional menu Appearance of the menu bar when displaying the control panel data Fig 3 Appearance of the menu bar after establishing connection with the control panel...

Page 12: ...is opened or connection with the control panel is established the side menu will display buttons which open the tabs used for configuration of the control panel settings 3 1 3 Additional menu The addi...

Page 13: ...d Data files encryption key if you want the files saved to disk to be additionally encrypted enter the file encryption key Opening the files in another PERFECTA SOFT program without entering the valid...

Page 14: ...control panel data the file with default settings New tab or the file saved on the computer disk Projects tab 3 Configure the settings required to establish connection see Connection window p 10 4 Cl...

Page 15: ...e LED on keypad indicating the partition armed status goes off If value 0 is programmed the LED will be ON always when the partition is armed 4 1 3 Arming Prevent arming if not ready Check if ready if...

Page 16: ...y if this option is enabled the control panel will also provide information about troubles that do not exist any more You can clear the trouble memory by using keypad when exiting the trouble review f...

Page 17: ...seconds it has no effect on the operation of the 19 TROUBLE STATUS type output which is activated immediately after AC power is lost AC loss report delay can be up to 60 minutes Tamper alarm on inter...

Page 18: ...nel to dial the number when some non standard tones occur on the telephone line after going off hook e g interrupted tone When this option is disabled the control panel will start dialing the number 3...

Page 19: ...l display mode and the zone presentation mode the key is to be pressed and hold down for about 3 seconds The option is not available for the wireless keypad Alarm 3 incorrect codes 3 wrng codes al if...

Page 20: ...alarms 258 New trouble volume level when signaling troubles 4 3 5 Wireless keypad PERFECTA T 32 WRL For the wireless keypad additional parameters and options are available Filter 1272 Filter the time...

Page 21: ...tions partition in which alarm will be triggered in the event of module tamper AC loss report delay 23 Max AC loss time during which the module must be without AC power before the AC power trouble is...

Page 22: ...rtition is a separated area within the premises protected by the security alarm system The subdivision into partitions enables arming disarming the system only in part of the protected area as well as...

Page 23: ...erent from 0 means activation of the burglary alarm verification function The verification consists in checking whether another zone will trigger the burglary alarm within the defined period of time I...

Page 24: ...available wireless zones depends on the number of wireless detectors registered in the system virtual zones which do not physically exist but are controlled by means of keyfobs 6 1 Zone parameters an...

Page 25: ...imilarly as in the event of 30 s for arming disarming keypad press the pulses are counted when the partition is armed or disarmed Arming disarming will reset the pulse counter Assigned to part 1 361 P...

Page 26: ...e If the option is enabled the zone restore will disarm the partition Store zone violations events 370 Viol event an option for the 12 NO ALARM ACTION zone type If the option is enabled the zone viola...

Page 27: ...delay countdown 17 SHUNT LOCK violation of the zone ends the partition exit delay countdown If the ZONE RESTORE DISARMS option is enabled the zone restore will disarm the partition 18 ENTRY ROUTE ENA...

Page 28: ...alarm 10 TAMPER ALARM output activated by triggering tamper alarm 11 FIRE DETECTORS POWER SUPPLY output for power supply of fire detectors with automatic alarm verification The output is deactivated...

Page 29: ...part 2 452 P 2 outputs if this option is enabled the output is controlled by events related to partition 2 alarm in partition 2 clearing alarm in partition 2 etc Polarity 453 Polarity the option defi...

Page 30: ...ion is received trouble will be reported Signaling 1275 Al signal alarm signaling mode Arm Disarm beep 1276 Acknowled signaling mode for arming disarming etc cf ARM DISARM CLEAR SIGN option Tamp in pa...

Page 31: ...control panel can send event codes to the monitoring station by using analog telephone line 9 1 Reporting parameters and options Fig 16 Reporting tab Reporting Monitoring if the option is enabled the...

Page 32: ...he keypad use the 732 SIA prefix 752 SIA prefix function If the identifier only consists of the digits 0 events are not sent Send names Names in SIA if the option is enabled in the SIA format the name...

Page 33: ...10 Messaging The control panel can send notifications about alarm system events by means of voice messages The voice messages which are to be used for notification should be saved to the control pane...

Page 34: ...s option is enabled the control panel can notify the users of events by using voice messages Event assignment For the events of which the control panel is to notify you must define the telephone numbe...

Page 35: ...outputs You can program 8 timers 11 1 Parameters and options of the timers TIMER n 59 Active if the option is enabled the timer is enabled n timer number Name 58 Names individual timer name up to 16...

Page 36: ...l be valid from to 25 Dec each year xxxx xx 12 the exception will be valid from to 12th day of each month in each year xxxx 03 xx the exception will be valid from the beginning of March each year same...

Page 37: ...he control panel offers 5 user schedules When adding or editing a user one of the user schedules is selected Changing the rights in user schedule results in a change of rights of all the users to whom...

Page 38: ...he OUTPUTS CTRL function Tests the user can view the event log set the clock check troubles system state and run the functions available in the TESTS submenu Service access the user can run the REPLAC...

Page 39: ...ter has been modified p 19 Description of AC loss report delay output expander parameter has been modified p 20 Description of Entry delay in Night Arm option has been added p 21 Description of Entry...

Reviews: