20
PERFECTA-T
SATEL
4.6 Output module
Fig. 11. Tab with output expander settings.
Name
[2815.Ex.0F name]
– individual name of the module (up to 16 characters).
Alarm in part.
[2215.Ex0F part]
– partition in which alarm will be triggered in the event of
module tamper.
AC loss report delay
[2315.AC.0F loss]
– time during which the module must be without AC
power before the AC power trouble is saved to the event log and reported to the
monitoring station. If you program 0, the AC trouble will neither be saved to the event log
nor reported to the monitoring station. This parameter applies to the module with power
supply.
5. Partitions
The partition is a separated area within the premises protected by the security alarm system.
The subdivision into partitions enables arming/disarming the system only in part of the
protected area, as well as limiting access to some portion of the premises to selected users.
You can create 2 partitions.
5.1 Partition parameters
Part. name
[18.Names]
– individual name of the partition (up to 16 characters).
Exit delay
[13.Exit delay]
– time counted from the moment of starting the procedure of
partition arming. It allows the user to leave the protected area without triggering alarm. You
can enter from 0 to 255 seconds. Entering zero 0 means no exit delay time.
The exit delay countdown can be terminated by using keypad (see E
XIT DELAY
CLEARING ENABLE
option) or zones of the 1. E
NTRY
/E
XIT FINAL
, 16. E
XIT
D
ELAY
T
ERMINATOR
or 17. S
HUNT
L
OCK
type.