4
PERFECTA-T
SATEL
1. Introduction
You can configure the PERFECTA alarm system by using:
a computer running the PERFECTA
S
OFT
program,
a keypad.
The control panel can be configured when the A
CTIVE
option is enabled (see U
SER MANUAL
).
As required by the standards, the service access after completion of the installation
has to be limited by the administrators.
Names of parameters and options from the PERFECTA
S
OFT
program are used in this
manual. At the description of each parameter or option, you will find one of the following data
in square brackets:
name of the function which is used for configuring a parameter or option on the keypad,
name of a parameter or option from the keypad.
2. Configuring the system by using keypad
You can configure the alarm system by using functions available in the service mode menu.
When the control panel is running in service mode, tamper alarms are not
generated.
2.1 Starting the service mode
1. Enter the
service code
(by default: 12345) and press
.
2. User menu appears.
3. Press
.
4. When the cursor shows the S
ERVICE MODE
function, press
.
5. Service mode menu will be displayed (the cursor will show the E
ND
SM function).
2.2
Starting the service mode “from pins”
When entering the service mode in the normal way is not possible (the control panel does not
support keypads, does not accept the service code, etc.), you can use the emergency
procedure, so-
called, starting “from pins”.
1. Turn off the control panel power supply (first disconnect the AC power, and then the
battery).
2. Put a jumper on the RESET pins on the control panel mainboard.
3. Turn on the control panel power supply (first connect the battery and then the AC power).
4. Wait a few seconds (until LEDs next to the RESET pins stop flashing) and remove the
jumper from the RESET pins. The control panel will enter the service mode. The service
mode menu will be displayed on the wired keypad with the lowest address.
If there is no wired keypad in the alarm system or there is no communication with the
wired keypads (e.g. when the communication bus is shorted), you can get access to
the service mode menu from the wireless keypad with the lowest address. Press any
key on this keypad within 30 seconds of removing jumper from the RESET pins.
The service mode menu will not be displayed, if the D
ISABLE
S
ERVICE
M
ODE
option is
enabled in the control panel. The “Factory settings ? 1=Yes” message will be