4.5 Impact of the EN 50131 standard on keypad use
If the control panel has been configured in accordance with the requirements of Standard
EN 50131 for Grade 2 (INTEGRA) or Grade 3 (INTEGRA Plus):
•
the keypad does not signal alarms,
•
the
LED indicates alarms only after entering the code,
•
flashing of the
LED indicates a trouble, bypassed zones or an alarm,
•
the
LED goes out after 60 seconds (Grade 3),
•
quick arming functions are not available,
•
arming procedure cannot be initiated, if there are violated zones in the partition or there is
a trouble in the system,
•
the partition will not be armed if, at the moment of completion of exit delay countdown:
– there is a violated zone in partition which was not violated when the arming procedure
was started,
– there is a trouble which did not exist when the arming procedure was started.
5. Specifications
Supply voltage .................................................................................................... 12 VDC ±15%
Standby current consumption .......................................................................................... 40 mA
Maximum current consumption ........................................................................................ 75 mA
Relay output (resistive load) ................................................................................. 1 A / 30 VDC
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range ............................................................................... -10°C...+55°C
Maximum humidity .......................................................................................................... 93±3%
Dimensions .................................................................................................... 80 x 127 x 24 mm
Weight ............................................................................................................................... 110 g