Relay

 [Relay type] – status of the deactivated relay: 

NO

 [Normal.open NO] – the relay contacts are open (they close on activating the relay). 

NC

 [Normal.closed NC] – the relay contacts are closed (they open on activating the relay). 

Authorization

 

control 

[Unauth. event] –  if this option is enabled, unauthorized opening of 

the door will save the event to the control panel memory. 

Alarm on unauth. access 

[Unauth. alarm] – if this option is enabled, unauthorized opening 

of the door when the partition is armed will trigger an alarm. The option is available if the 
“Authorization control” option is enabled. 

Max. door open time

 [Max. door open] – the maximum period of time during which the door 

can be open (the door status input can be disconnected from common ground). If the door 
is open longer, audible alarm will be triggered in the keypad, and the event will be saved to 
the control panel memory. You can enter from the 0 to 255 seconds. If you enter 0, the 
door can be open for any long period of time. 

Dependent on door (1)

  / 

Dependent on door (2)

  –  you can select the door that must be 

closed so that the user can get access (turn the relay output on). It allows you to create an 
airlock. You may select a door supervised by another expander or alarm system zone 
programmed as type “57 Technical – door open”. 

Confirmation

 – method of providing feedback to the user after using the keypad: 

No

 – no feedback. 

Sound

 – the keypad will use sounds to give feedback to the user. 

Backlight

 – the keypad will use key backlight to give feedback to the user. 

Code+* do not disarm

  [Code*  not dis.] –  if this option is enabled, entering the code and 

pressing 

 will not disarm the partition (to disarm the partition, the user must enter the 

code and press 

). 

Access if armed 

[Code* in arm] – if the option is enabled, the users can gain access (turn 

the relay output on) when the partition is armed. If the option is disabled, the users cannot 
gain access when the partition is armed. The option is available, if the “Code+* do not 
disarm” option is enabled. The option does not apply to the “ON if partition armed” mode. 

Users

 [Master users / Users] – the administrators and users which are permitted to use the 

keypad. 

FIRE alarm

 – if this option is enabled, pressing and holding 

 for 3 seconds will trigger 

the fire alarm. 

AUX. alarm 

[Medical alarm] –  if this option is enabled, pressing and holding 

  for  3 

seconds will trigger the medical alarm. 

PANIC

 

alarm 

– if this option is enabled, pressing and holding 

 for 3 seconds will trigger 

the panic alarm. 

silent

 [Silent panic] – if this option is enabled, the panic alarm triggered from the keypad will 

be a silent one, i.e. the keypad will not indicate it, there will be no audible signal, but the 
alarm will be reported to the monitoring station. The silent panic alarm is useful when the 
control panel is sending events to the monitoring station, but unauthorized persons should 
not be aware of the alarm being triggered. This option is available, if the “PANIC alarm” 
option is enabled. 

Alarm 3 incorrect codes

 [3 wrong codes] – if this option is enabled, entering a wrong code 

three times will trigger an alarm. 

Quick  arming

  [Quick arm] –  if this option is enabled, the user needs no code to arm the 

partition using the keypad. 

Control “BI”

 

output 

[BI outs ctrl.] – if this option is enabled, the ““Bi” output operating” type 

of users can use the keypad to control outputs. 

Summary of Contents for INT-S Series

Page 1: ...INT S Partition keypad Firmware version 2 02 int s_en 07 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the change...

Page 3: ...ndicators 8 4 2 Sound signaling 8 4 2 1 Beeps generated when operating 8 4 2 2 Signaling events 8 4 3 Code 9 4 4 Available functions 9 4 4 1 Code 9 4 4 2 Code 10 4 4 3 Quick arming 10 4 4 4 Triggering...

Page 4: ...INT S partition keypad with closed and open flap cover 1 Features Arming disarming and alarm clearing in partition Capability of triggering alarm from the keypad Single door control relay output for c...

Page 5: ...d pair type of cable remember that CLK clock and DTA data signals must not be sent through one twisted pair cable The wires must be run in one cable 8 If the partition keypad is to control an electric...

Page 6: ...2 Description of terminals NO relay output 12V power input DTA data expander communication bus CLK clock expander communication bus COM common ground IN door status input NC 3 Configuring The keypad s...

Page 7: ...cess the user must disarm the partition Fixed ON time ON time the relay output will be turned on for the Relay ON time Fixed ON time OFF if door open ON open off the relay output will be turned on unt...

Page 8: ...is option is enabled entering the code and pressing will not disarm the partition to disarm the partition the user must enter the code and press Access if armed Code in arm if the option is enabled th...

Page 9: ...Auto arm delay if this option is enabled the partition keypad will audibly signal the auto arm delay countdown Acc code sign hardware Code entered if this option is enabled the partition keypad will c...

Page 10: ...icate that there is no communication with the control panel 4 2 Sound signaling 4 2 1 Beeps generated when operating The installer can disable the sound signaling or replace it with flashing of the ke...

Page 11: ...ontrol panel service code 12345 object 1 master user administrator code 1111 The factory default codes should be changed before you start using your alarm system Do not make your code available to oth...

Page 12: ...art the partition arming procedure if the exit delay is 0 the partition will be armed instantly 4 4 4 Triggering the alarm from keypad The installer can permit triggering alarms from the keypad To tri...

Page 13: ...cannot be initiated if there are violated zones in the partition or there is a trouble in the system the partition will not be armed if at the moment of completion of exit delay countdown there is a...

Reviews: