GSM-4S SATEL
7
Management of SMS text messages is signaled on the module display with the following
reports:
“SMS sent”
– after transmitting SMS text message via SIM300CZ telephone.
“SMS received”
–
after receiving text message containing SMS password
pre-programmed in the module.
“Unknown SMS rec.” –
after receiving SMS message not containing the password
pre-programmed in the module.
Situated below the display are four keys (push-buttons) intended for programming the
module and for manually controlling operation of the module inputs and outputs.
Push-button
number
Push-button description
1
ESC
2
CHANGE
3
NEXT
4
OK
The number of push-buttons given in table above correspond to the number of inputs and
outputs during manual control.
Simultaneous pressing and holding for one second both push-buttons, ESC and OK., makes
the restart of the module, with program version being displayed on LCD display. The restart
of the module does not change the status of inputs and outputs. In case of the loss, and then
the restoration of power supply of the module, its inputs and outputs are restored to the
status before the disconnection of power supply.
The cables of telephone lines: public exchange line (subscriber’s) and extension line (to the
alarm control panel and telephone set) can be connected to the terminal strip or to the
telephone jacks located on the board.
4. O
PERATING THE
SIM300CZ
TELEPHONE
The SIM300CZ industrial cellular telephone, similar as any other cellular telephone, can be
operated by SIM activation card. The user of the GSM-4S module and the SIM300CZ
telephone has to obtain such card. The SIM card is inserted into a special socket provided at
the bottom of the printed circuit board. PIN code, if necessary, is entered in the module’s
memory by the service function from the sub-menu "GSM options". The change of PIN code
or entering PUK code, if needed, is only possible after putting the SIM card into an ordinary
cellular telephone.
The SIM300CZ cellular telephone set is delivered with special cable fitted, having
a connector for external antenna (see fig. 2).
5. I
NSTALLATION
It should be remembered during installation that the GSM-4S module must not be located in
the vicinity of electrical installations, since this may involve a risk of malfunctioning. Pay
special attention to how the cable is laid between the module and the telephone jack of the
alarm control panel.
Caution:
Never turn on power supply of the module and SIM300CZ telephone
without external antenna connected.