1. GSM-4S

 MODULE FEATURES

 

  Simulation of analog telephone line by the use of cellular connection – which makes it 

possible to report an alarm situation at the site in case the analog line is out of order or 
missing. 

  Operation with alarm control panels and with other equipment (e. g. DT-1 telephone set) 

using the telephone line for transmitting voice information about the alarm, or for sending 
text messages to paging system. 

 Operation in conjunction with the STAM-1/STAM-2 monitoring station, which makes 

monitoring of the sites possible with the use of SMS short messages. 

  Function of an external modem for the INTEGRA alarm control panels (support of 

DLOADX and GUARDX programs) and the CA-64 alarm control panels (support of 
DLOAD64 and GUARD64 programs)*. 

  Answering incoming and making outgoing calls via cable telephone network and via 

mobile communication system (cellular network). 

  Optional selection of the basic outgoing line: GSM/cable (subscriber line). 

  Signaling of answering (receiving) a call initiated from the module T-1, R-1 terminals by 

changing the voltage polarization across those terminals (possibility of tariffication).  

  Operation with PBX telephone exchange as additional subscriber’s line. 

  Pulse and tone dialing modes. 

  Substitution of the direct access to cable telephone network and the access to cable 

telephone network via PBX. 

  Four inputs, the violation of which (and restoring to normal status) can be monitored by 

SMS messages, voice messages or CLIP. 

  Three outputs for controlling the electrical devices (e. g. by relays directly connected to the 

module). 

  Output for signaling the telephone line failure and the cellular line failure. 

  Test messaging (monitoring) in order to confirm the module operative condition 

  Possibility to control the outputs activity by violating the inputs (e.g. tripping alarm device 

after actuation of an alarm sensor) or by CLIP. 

  Remote controlling of the status of module’s outputs and bypassing of the module inputs 

by using SMS text message or dual tone phone push-buttons (DTMF Signals). 

  Capability of recognizing the message directed to paging system and transmitting it in the 

form of SMS text message to any cellular telephone number. SMS messages are always 
sent, irrespective of availability of subscriber’s telephone line. 

  Possibility of restricting the access to cellular telephone by making connections to 32 

precisely defined numbers, or reduction of available numbers by assigning initial digits to 
such numbers. 

  Operation with SIM300CZ three-range professional cellular telephone, compatible with 

GSM 900/1800/1900 Mhz networks. 

  Checking for cellular telephone availability and for antenna signal level. 

  Remote programming of the module from PC computer by using the DLOAD10 program. 

  RS interface (connecting to computer, INTEGRA or CA-64). 

  GPRS monitoring, including the GSM-4S module status and/or control panel events 

(simulation of telephone monitoring station reading events in DTMF formats). 

  Answering the user CLIP (by means of a CLIP, SMS or VOICE message). 

*

 – function available for the CA-64 control panel with v1.04.03 program and DLOAD64 v1.04.04 and GUARD64 

v1.04.03 programs (or later versions). 

Summary of Contents for GSM-4S

Page 1: ...COMMUNICATION MODULE GSM 4S USER MANUAL Program version 4 11 gsm4_en 07 08...

Page 2: ...S Manufacturer SATEL sp ka z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 fax 48 58 320 94 01 Product description The GSM 4S communication module designed to interact with the SIM300CZ...

Page 3: ...SSAGING 17 10 1 SMS MESSAGES 18 10 2 VOICE MESSAGING 18 10 3 CLIP 19 10 3 1 CLIP with acknowledgement 19 10 3 2 CLIP without acknowledgement 19 11 TRANSMITTING SMS MESSAGES 20 11 1 DESCRIPTION OF THE...

Page 4: ...LIP Three outputs for controlling the electrical devices e g by relays directly connected to the module Output for signaling the telephone line failure and the cellular line failure Test messaging mon...

Page 5: ...f cellular telephone can generate the proper form of these signals Some models of cellular telephone have a special function permitting the DTMF control in such case this special function is to be act...

Page 6: ...nd essential elements which are important for connecting and programming the GSM 4S module For power supply of external equipment you should use the V V outputs whose max current load must not exceed...

Page 7: ...nu The SIM300CZ telephone will not start dialing if the antenna signal level is equal to zero The status of inputs and outputs are displayed alternately 2 s 2 s at last four characters of top line on...

Page 8: ...picked up connection type modem connection voice connection telephone number or message status of inputs outputs see table 1 antenna signal level RS 232 port receiving data sending data GSM telephone...

Page 9: ...bles of telephone lines public exchange line subscriber s and extension line to the alarm control panel and telephone set can be connected to the terminal strip or to the telephone jacks located on th...

Page 10: ...he countdown to make possible a change of the PIN code for the right one The GSM phone trbl message is shown on the display until the SIM300CZ telephone logs in the cellular network This state may las...

Page 11: ...ne number and then initiates dialing and getting connection via the SIM300CZ telephone The corrections are necessary since the module gets the dialed telephone number as when connecting via the cable...

Page 12: ...monitoring station from version 4 07 only supports SMS monitoring related to the input status of the GSM module located on the site e g GSM 4S or GSM LT 2S Changing the status of the device inputs wil...

Page 13: ...lowing way enabling output if inactive the output will be switched on if active the output status will not change If a cut off time has been programmed for the output it will be disabled after the tim...

Page 14: ...passing option can be disabled by deselecting IN1 bps manual option The remote control is implemented similarly to the remote control of the module outputs status The input can be automatically bypass...

Page 15: ...nd generate three short sounds beeps acknowledging that the module is ready to have the DTMF controlling Note When receiving a call the module applies ringing tone to extension line for the duration e...

Page 16: ...ne number After decoding the password by the module an appropriate action will be initiated depending on the password transmitted E G Recognizing the password entered into the module memory by the fun...

Page 17: ...line in good working order the telephone line out of order In the test field the module will send the currently programmed number of days hours and minutes of the test transmission period In the tele...

Page 18: ...controlling OT2 bypassing IN2 NEXT controlling OT3 bypassing IN3 OK switching OFF all outputs bypassing IN4 The manual bypassing unbypassing the inputs is also implemented by the GSM 4S module s push...

Page 19: ...g a given number twice two phone connections with replaying the message each time Another form of messaging is the test transmission In order to inform the user of its operability the module will send...

Page 20: ...rom SMS will be displayed on LCD display and the module will go into awaiting for SMS message mode for the duration of approx 110 seconds Send SMS message previously prepared from another cellular tel...

Page 21: ...an option to early reject the connection but if he carries out this action too early the module will repeat the call Answering the call either by the user or automatically by the voice mail is recogni...

Page 22: ...l be active and also determine the way of messaging SMS CLIP VOICE functions In 1 4 Tel Rest 1 Tel F L Tel Rest L Tel Test Tel If the voice messaging is selected and several inputs can activate this m...

Page 23: ...2 2 A 0 E 0 0 7 A 8 11 2 SENDING SMS MESSAGES FROM A STATIONARY TELEPHONE SET The GSM 4S module user has an option to send SMS messages form a stationary telephone set which generates DTMF signals an...

Page 24: ...espond to the pager station number or any of the outgoing numbers 4 seconds since dialing the last digit the module will recognize the dialing as completed and will proceed to convert the number If an...

Page 25: ...d consider the monitoring attempt unsuccessful After a specified number of unsuccessful attempts function Num pan attempts the module can send an SMS message its contents is determined by function GPR...

Page 26: ...gram with the default access code 1234 module DSR module RTS module RXD module TXD COM SERIAL PORT RS 232 view of connector at the GSM 4 module board comp DTR comp CTS comp TXD comp RXD GND 2 3 4 5 8...

Page 27: ...module by clicking on the icon 8 If necessary you can save the programmed data as a file on the computer disk 9 Disconnect the cable used for programming Note Never carry out functional test of the m...

Page 28: ...ure 11 This tab allows the user to configure the basic working parameters of the module The parameters programmable in the GSM 4 tab correspond to the control functions and have been reviewed in secti...

Page 29: ...G TAB Figure 12 The tab enables messaging parameters to be configured The parameters programmable in the Telephone messaging tab correspond to the control functions and have been reviewed in section D...

Page 30: ...28 13 3 CONTROL INPUTS OUTPUTS TAB Figure 13 The parameters programmable in the Control Inputs Outputs tab correspond to the control functions and have been reviewed in section Description of service...

Page 31: ...ransmission data are not programmed All the options are discussed in detail in section Description of service functions page 36 Monitoring the module inputs requires that the format and codes of event...

Page 32: ...module to display a suitable message and wait for entering the code Unless the entered code is valid the module will only enable the user to enter the service mode when all the settings are deleted T...

Page 33: ...o 3 Outgoing no 4 Perm prefix 1 Perm prefix 2 Perm prefix 3 Perm prefix 4 Prefix to erase Prefix to add Allowed numbers Tel No 1 begin Tel No 2 begin Tel No 32 begin Messaging Tel 1 for mess Tel 2 for...

Page 34: ...L ok mess IN4 IN1 Tel IN2 Tel IN3 Tel IN4 Tel F L Tel Rest 1 Tel Rest 2 Tel Rest 3 Tel Rest 4 Tel Rest L Tel Test Tel Test period Mess priority Mess sounds SMS control SMS bypass IN1 SMS bypass IN2 SM...

Page 35: ...IN3 DTMF unbyps IN4 DTMF unbyps all DTMF check inps DTMF OT1 on DTMF OT2 on DTMF OT3 on DTMF OT1 off DTMF OT2 off DTMF OT3 off DTMF chng OT1 DTMF chng OT2 DTMF chng OT3 DTMF OT123 off DTMF OT123 on DT...

Page 36: ...1 bps manual IN2 bps manual IN3 bps manual IN4 bps manual Bypassing input Bypassed inputs OT1 cut off t OT2 cut off t OT3 cut off t OT3 t l trbl OT4 only GSM IN1 Outputs IN2 Outputs IN3 Outputs IN4 Ou...

Page 37: ...SMS Skip audio St 1 SMS tel n St 2 SMS tel n St 1 SMS format St 2 SMS format Num pan attempts GPRS trouble tel GPRS trbl SMS IN1 violat code IN2 violat code IN3 violat code IN4 violat code IN1 restore...

Page 38: ...xt field to the right or return to the first field on the left side of the number or password entered Pressing the push button OK results in storing the entered data and in exiting from the function 1...

Page 39: ...minals If this option is unchecked the cable line is the basic one Trbl switch l when this option is selected the module in case of cable telephone line failure will automatically switch over to makin...

Page 40: ...nt to telephone nos 1 4 SMS mess 1 4 fail if you select this option an SMS message will be sent to the telephone number if the module having completed all the attempts receives no acknowledgement of t...

Page 41: ...messaging When this option is not set the messaging shall be sent after the user hangs up Mess sounds setting this option for voice messaging makes the module generate sounds informing which inputs ha...

Page 42: ...test transmission 1 transmission period equal to 2 h 58 min 2 transmission period equal to 5 h 57 min 3 transmission period equal to 11 h56 min 4 transmission period equal to 23 h55 min 5 transmissio...

Page 43: ...nsit the sensitivity of each input The following values in msec can be programmed 20 40 60 80 100 130 160 200 250 300 400 500 600 800 1000 1275 Input 1 4 restore time from the end of violation after w...

Page 44: ...ut s 6 check output status in response the device will generate beeps o 1 short beep output disabled o 2 short beeps output enabled Controllable out selection of outputs which can be locally enabled d...

Page 45: ...when the Station address is to be entered in mnemonic form 4 bytes 000 000 000 000 each of which can take the value from 0 to 255 Tst INTEGRA cn test the status of connection to INTEGRA control panel...

Page 46: ...nning end of violation event code I zone module user J partition For 4 2 format events the form will be Event iiii cc 20 ASCII characters and for Contact ID format Event iiii q ccc ss xxx 24 ASCII cha...

Page 47: ...ogrammed modem for another one by means of an SMS message format code modem format 00 auto 01 300 V 21 02 1200 V 22 03 1200 75 V 23 04 2400 V 22bis 05 2400 V 26ter 06 4800 V 32 07 9600 V 32 12 9600 V...

Page 48: ...elds Outgoing No 1 4 not necessarily in two first fields The changes entered in the service functions have in majority immediate results i e immediately after the exit from the function by pressing pu...

Page 49: ...telephone number of the Service While programming at the alarm control panel the telephone numbers for messaging it is required to choose one of three ways of getting connection the letter D indicates...

Page 50: ...code e g for Poland 48 instead of 48 17 TECHNICAL DATA Supply voltage 12 V DC 15 Outputs current carrying capacity 4 x 50 mA Current carrying capacity supply output V V 300 mA Maximum current consump...

Page 51: ...SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...