SATEL
GPRS-T2
19
You can also make use of the code editor. To open the code editor, click on the button
designated with three dots, available in the "EVENT" filed.
Violation/pass Partition / Restore Partition
– partition number which will be sent in
the event code. You can enter numbers and letters from A to F.
Note: If events are to be sent in the form of two characters (partition number only), you
should not use the code editor.
Violation/pass Zone n. / Restore Zone n.
– zone / module / user number which will be sent
in the event code.
Violation/pass Event / Restore Event
– this field displays description of the event, whose
code is entered in the "CODE" field. Available in the "EVENT" field is also the button
designated with three dots, which enables opening of the code editor.
Note: For the analog inputs, the reporting related parameters are to be determined
separately for each of the defined thresholds.
4.4 S
TARTING
GPRS
REPORTING
1. Enter the GPRS communication parameters ("GSM telephone, Monitoring stations" tab):
– Access Point Name (APN) for Internet GPRS connection;
– user name for Internet GPRS connection;
– password for Internet GPRS connection;
– DNS server IP address which is to be used by the module (the DNS server address
requires no programming, if the IP address is entered for the monitoring station).
– password initializing connection with the computer.
2. Configure parameters of the monitoring station(s) ("GSM telephone, Monitoring stations"
tab):
– select the "GPRS" option;
– enter the monitoring station address ("Address (GPRS)" field);
– enter the number of TCP port through which communication with the monitoring station
will be effected;
– enter the encryption key for data to be sent to the monitoring station ("Station key");
– enter the GPRS key.
3. Determine the operation mode for the inputs, the status of which is to be monitored
("Inputs" tab):
– define the input type (digital of NO or NC type or analog);
– define the "Sensitivity" and "Restore" parameters for the inputs (for the AC input only
the "Sensitivity" parameter);
– define additionally the "L threshold", "H threshold" and "Tolerance" parameters for the
analog inputs.
4. Define the status of which inputs and how is to be monitored ("Reporting" table, "Inputs"
tab):
– indicate the monitoring station to which the event code is to be sent;
– program the event code which is to be sent;
– enter the partition number which will be sent in the event code;
– enter the zone / module / user number which will be sent in the event code.