PECIFICATIONS

 

Supply voltage ................................................................................................... 12 V DC ±15% 

Current consumption, standby .........................................................................................75 mA 

Current consumption, max. ............................................................................................ 400 mA 

Power supply required output current, min. .......................................................................... 2 A 

Permissible voltage at AC input ........................................................................... up to 25 V AC 

Current-carrying capacity, FT output ................................................................................50 mA 

Maximum relay switching capacity (resistive load) ............................................... 2 A / 30 V DC 

Environmental class ................................................................................................................. II 

Working temperature range .................................................................................... -10...+55 °C 

Electronics board dimensions ................................................................................. 80 x 57 mm 

Weight ............................................................................................................................... 190 g 

 

 

Summary of Contents for GPRS-T2

Page 1: ...GPRS SMS Reporting Module GPRS T2 Program version 2 01 gprs t2_en 11 11 SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 320 94 00 info satel pl www satel eu ...

Page 2: ...ule that enables GPRS SMS CLIP reporting triggered by unit s inputs intended for intruder alarm systems The product is in conformity with the following EU Directives RTTE 1999 5 EC EMC 2004 108 EC LVD 2006 95 EC The product meets the requirements of harmonized standards EN 50130 4 1995 A1 1998 A2 2003 EN 61000 6 1 2007 EN55022 2006 A1 2007 EN 61000 6 3 2007 EN 60950 1 2006 EN 301 489 7 V1 3 1 EN 3...

Page 3: ...Event codes are sent in the form of GPRS transmission or SMS messages Using the GPRS technology makes it possible to send the codes to the STAM 2 monitoring station or SMET 256 converter The codes in SMS format can be sent to any monitoring station which supports the SMS reporting feature In order to execute some functions the module makes use of the features offered by the CLIP service which enab...

Page 4: ...ty s telephone number CLIP service after receiving command from the GPRS SOFT program Option to check the status of available resources and account validity of the SIM card installed in the module Indicator of GSM signal level received by industrial cellular telephone and an indicator of troubles connected with logging into the GSM network Relay output of NO type controlled locally by means of inp...

Page 5: ...mples of LED indicated statuses A LED A is blinking the other LEDs are lit up GPRS transmission is going on signal level 3 B LED B is blinking the other LEDs are lit up SMS message is being sent or module is calling CLIP test transmission signal level 4 C LEDs are blinking logging into GSM network D LEDs are blinking logging into GSM network has failed missing SIM card E LEDs are blinking logging ...

Page 6: ...thick walls metal partitions etc will reduce the radio signal range Installation in close vicinity of electrical systems is not recommended as it may adversely affect the device performance The module power supply source should provide sufficient output current and be equipped with a battery Fig 4 Example of connecting power supply and testing AC voltage presence in GPRS T2 module 1 transformer 2 ...

Page 7: ... supply 10 Insert the SIM card into the socket see Fig 5 11 Turn on the module power supply Logging the telephone into the GSM network may take a few minutes Note If the SIM card PIN code is inconsistent with that defined in module settings the inconsistency will be indicated by the electronics board LEDs see Fig 3 Example F The second attempt of using the PIN code will be made after 30 seconds Af...

Page 8: ...er must be connected with the RS 232 TTL port on the module electronics board The cables for making this connection are available as a set designated DB9FC RJ KPL Indicate in the GPRS SOFT program the computer COM port to be used for communication with the module To do so click on the Configuration button see Fig 7 and explanations for the figure and in the window that will open select one of the ...

Page 9: ... establish communication between the module and the computer do the following 1 Start the GPRS SOFT program 2 Click on the Configuration button see Fig 7 and explanations for the figure and in the window that will open enter the number of TCP port selected for communication with the module The number will have to be included in the body of SMS message which will be sent to the module GSM telephone...

Page 10: ...GPRS technology and TCP IP protocol a click on the button will simultaneously open a window indicating the server status The button color indicates the current communication status green computer COM port enabled server active gray computer COM port disabled server inactive 9 button for selecting the mode of communication with the module local programming through the RS 232 port or remote programm...

Page 11: ...can be saved into the module or enter another one and save it Remote programming enable this option if remote programming of the module with the use of GPRS technology is to be available Initiating number only from list of telephone numbers for messaging if this option is enabled the SMS message initiating the remote programming must be sent from a telephone whose number is stored in the module me...

Page 12: ...ute the USSD code contained therein The answer received from the operator is sent in the form of SMS message to the telephone number from which the control command was sent Note Using the advanced functions available due to the USSD service when menu is presented in reply to the code entered is not recommended Autorestart every if the restart of module settings is to be periodically repeated you m...

Page 13: ... not enter value 0000 the module will not be sending test transmissions to the monitoring station Using digit 0 in the identifier is not recommended Telephone numbers for messaging and test transmissions It is possible to program 4 telephone numbers to which the module will be able to send SMS messages if specific event codes are received and also to send test transmissions The telephone number mu...

Page 14: ...t code to be sent Event codes for module test transmission The table makes it possible to define the codes which will be sent to the monitoring stations for the module test transmission Format the field displays information that the code is sent in the Contact ID format CODE program 3 digits of the event code in this field You can also make use of the code editor To open the code editor window cli...

Page 15: ...ssible to determine in detail how the CLIP test transmissions are to be sent to the four telephone numbers programmed in the GSM telephone Monitoring stations tab Click twice on the chosen field to select deselect it the field is selected if x symbol is displayed in it Acknowledgement select this field if the module is to wait for the acknowledgement of receipt of test transmission using the CLIP ...

Page 16: ...ansmission or SMS message with status information when the telephone number identified owing to the CLIP service is one of the numbers programmed in the GSM telephone Monitoring stations tab on the Telephone numbers for messaging and test transmissions list Note If the Reaction to CLIP only when number is on list of telephones for messaging option is not enabled the test transmissions and SMS mess...

Page 17: ...ontain up to 24 characters 4 3 4 INPUTS TAB Inputs The table enables programming the working parameters of Z1 Z5 inputs and AC input Note For the AC input it is only possible to program the Sensitivity parameter values up to 99 minutes and 59 seconds can be entered and define whether and how it is to control the output Type the input can be programmed as digital NC type enter digit 1 digital NO ty...

Page 18: ...ing input Blocked select this field if the input is to be blocked after violation of the blocking input or sending the SMS message the content of which can be defined in the tab Test transmissions control L threshold the lower voltage threshold for analog input If the voltage drops below the defined value minus tolerance the module will register input violation Entering value 0 means that the volt...

Page 19: ... inputs Output the field defines whether the input is to control the output The following options are available blank field input status does not control the output ON violation of the input or exceeding the voltage value at threshold L or H as defined for the input will enable the output ON for time violation of the input or exceeding the voltage value at threshold L or H as defined for the input...

Page 20: ...tore content of the SMS message that will be sent on restoration of the input to its normal state The message may consist of up to 24 characters If the field is left blank the message will not be sent Add input voltage value to message if this option is selected information on the current voltage value at the input will be added to the SMS message about the analog input status Note For the analog ...

Page 21: ...net GPRS connection DNS server IP address which is to be used by the module the DNS server address requires no programming if the IP address is entered for the monitoring station password initializing connection with the computer 2 Configure parameters of the monitoring station s GSM telephone Monitoring stations tab select the GPRS option enter the monitoring station address Address GPRS field en...

Page 22: ...ING The SMS or CLIP messaging is conducted irrespective of the monitoring 1 Enter the telephone number of Short Message Service Center SMS center number field in the GSM telephone Monitoring stations tab 2 Enter the telephone numbers which are to be notified by the module using the SMS messages or CLIP service Telephone numbers for messaging and test transmissions table in the GSM telephone Monito...

Page 23: ... displayed in which you should confirm your intention to restore the module factory defaults Most parameters in the factory default settings are not defined and the options are not enabled Only the following parameters are defined GSM telephone Monitoring stations tab Monitoring station 1 2 Disabled the field is selected SMS format Event Test transmission Control tab CLIP Reaction to CLIP only whe...

Page 24: ... max 400 mA Power supply required output current min 2 A Permissible voltage at AC input up to 25 V AC Current carrying capacity FT output 50 mA Maximum relay switching capacity resistive load 2 A 30 V DC Environmental class II Working temperature range 10 55 C Electronics board dimensions 80 x 57 mm Weight 190 g ...