INTEGRA Installer
Manual
7
INT-RS. Data converter.
Makes it possible to connect a computer with G
UARD
X program
installed, similarly as to LCD keypad, monitor events by using a special external device,
and operate the control panel by means of software other than that offered by SATEL.
3.3.2 Modules to be connected to expander bus
INT-S-GR/INT-S-BL/INT-SK-GR. Partition Keypad.
Controls the armed mode in one
partition; can perform the access control functions and operate the electromagnetic door
lock.
INT-SCR-BL.
Depending on its settings, the device can work as a
partition keypad
(identified as INT-S in the control panel), a
partition keypad with reader
(identified as
INT-SCR in the control panel) or an
entry keypad
(identified as INT-ENT in the control
panel). If it operates as a partition keypad or a partition keypad with reader, the device
can control arming of one partition, execute access control functions, and control
operation of the electromagnetic door lock. The main task of the entry keypad is
activation the delay for zones with reaction type 3 I
NTERIOR DELAYED
. After the time
period programmed in the keypad has elapsed and the system has not been disarmed,
the interior delayed zones will operate again as the instant ones.
INT-SZ-GR/INT-SZ-BL/INT-SZK-GR. Code Lock.
Enables performance of the access
control functions and operation of the electromagnetic door lock.
CA-64 SR. Expander of Proximity Card Reader.
Supports the SATEL made proximity card
readers to enable performance of the access control functions and operation of the
electromagnetic door lock.
CA-64 DR. Expander of "DALLAS" Chip Readers.
Supports the DALLAS chip readers to
enable performance of the access control functions and operation of the
electromagnetic door lock.
CA-64 E Zone Expander.
Enables the system expansion by 8 zones. The expander with
electronics in version 2.1 (or later) and firmware in version 2.0 (or later), where the
DIP-switch 8 is set in ON position, will be identified by the control panel as CA-64 Ei.
Roller shutter motion detectors (rope detectors) and vibration detectors (2 additional line
types) can be connected to the CA-64 Ei expander zones.
CA-64 EPS Zone Expander with Power Supply.
Enables the system expansion by
8 zones. Equipped with a 2.2 A built-in switching mode power supply. The expander
with electronics in version 2.1 (or later) and firmware in version 2.0 (or later), where the
DIP-switch 8 is set in ON position, will be identified by the control panel as CA-64 Ei.
Roller shutter motion detectors (rope detectors) and vibration detectors (2 additional line
types) can be connected to the CA-64 Ei expander zones.
CA-64 ADR Addressable Zone Expander.
Enables the system expansion by 48 zones.
Equipped with a 2.2 A built-in switching mode power supply. The INTEGRA control
panels support the addressable zone expanders having firmware in version v1.5 or
later.
CA-64 O-OC/CA-64 O-R/CA-64 O-ROC. Output Expander.
Enables expansion of the
system by 8 outputs. Made in three versions: 8 OC type outputs, 8 relay outputs and
4 relay outputs/4 OC outputs.
INT-ORS. DIN-rail outputs expander.
Enables the system to be expanded by 8 relay
outputs. The relays can control the electrical devices
supplied with 230 V AC voltage.
Note:
If the sixth DIP-switch in the INT-ORS expander is set in the upper position, the device
will be identified by the control panel as the CA-64 O outputs expander.
CA-64 OPS-OC/CA-64 OPS-R/CA-64 OPS-ROC. Output Expander with Power Supply.
Enables expansion of the system by 8 outputs. Made in three versions: 8 OC type