5
3. System Components
3.1 Mainboards
Show in the table below are technical parameters of the alarm systems based on particular
control panels of the INTEGRA family.
Technical parameter (quantity)
INTEGRA
24
INTEGRA
32
INTEGRA
64
INTEGRA
128
Security Grade
3
Available messaging options
A, B, C
Zones, mainboard
4
8
16
16
Zones,
system
24 32 64 128
High-current outputs, programmable,
mainboard
2 2 4 4
Dedicated power outputs for keypads,
expanders and detectors
3 3 2 2
Outputs, OC type, mainboard
2
6
12
12
Outputs, system
20+4*
32
64
128
Connectors for voice synthesizers
1
1
2
2
Keypads,
system
4 4 8 8
Expander
buses
1 1 2 2
Expanders,
system
32 32 64 64
Zone
expanders
2 3 6 14
Output
expanders
2 3 6 14
Objects
1 4 8 8
Partitions 4
16
32
32
Timers
16 32 64 64
Telephone numbers for messaging
4
8
16
16
Pager
messages
16 32 64 64
Voice
messages
16 16 16 32
Remote
switches
16 16 16 32
Users (w/o master user and service)
16
64
192
240
Event log
899
899
6143
22527
Power supply capacity [A]
1.2
1.2
3
3
Battery charging current [mA]
350
400/800
500/1000 500/1000
Current capacity, programmable outputs:
high-current / OC [A]
2 / 0.05
2 / 0.05
3 / 0.05
3 / 0.05
Current capacity, power-supply outputs:
+KPD / +EX1 with +EX2 [A]
-
-
2.5 / 2.5
2.5 / 2.5
+KPD / +EX / AUX [A]
0.5/0.5/0.5 0.5/0.5/0.5
-
-
* 20 physically available outputs (mai expanders) + 4 virtual outputs (to perform logical functions – see
description of output types 46 and 47).
•
Zones programmed individually to handle configurations with or without end-of-line resistor
(NO, NC, EOL, 2EOL/NO and 2EOL/NC) with functional test of the detector. The zone
status may also depend on the output status (if this is the case, the selected output does
not need to be physically connected to a zone, which enables virtual zones and outputs to
be used in the system). One of a few dozens of response types can be chosen for each
zone.