background image

The ASW-210 controller enables 230 V AC wired devices to be remotely switched ON/OFF. 
Additionally, the controller inputs make it possible to manually control these devices by using 
wired switches. The controller is designed to work as part of the ABAX 2 / ABAX two-way 
wireless system. This manual applies to the controller with firmware version 1.0, which is 
supported by: 

 ABAX 

2: 

– ACU-220 

ACU-280 controller, 

–  ARU-200 repeater.  

 ABAX: 

–  ACU-120 / ACU-270 controller (firmware version 5.05 or newer), 
–  ARU-100 repeater (firmware version 2.02 or newer), 
–  INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware 

version of processor used to operate ABAX system 3.11 or newer). 

1.  Features 

  2 programmable relay outputs (which can be controlled by using the monostable or 

bistable switch). 

  Galvanic isolation of the controller outputs. 

  2 programmable wired inputs (support for NO or NC type switches). 

  Encrypted two-way radio communication in the 868 MHz frequency band (AES standard 

for the ABAX 2 system). 

  Transmission channel diversity – 4 channels for automatic selection of the one that will 

enable transmission without interference with other signals in the 868 MHz frequency 
band (ABAX 2 system only). 

  Remote update of detector firmware (ABAX 2 system only). 

 Remote 

configuration. 

  Mounted in in-wall and on-wall electrical junction boxes with a minimum diameter of 

60 mm. 

2.  Specifications 

Operating frequency band ...................................................................868.0 MHz ÷ 868.6 MHz 
Radio communication range (in open area) 

ABAX 2 

ACU-220 .............................................................................................. up to 1000 m 
ACU-280 .............................................................................................. up to 1000 m 

ABAX.............................................................................................................. up to 500 m 

Supply voltage ................................................................................. 230 V AC ±15%, 50-60 Hz 
Standby current consumption .........................................................................................5.5 mA 
Maximum current consumption........................................................................................13 mA 
Rated switching voltage ..............................................................................................250 V AC 
Relay outputs rated load – AC1 ......................................................................... 5 A / 250 V AC 
Minimum switching current ..............................................................................................10 mA 
Rated switching current ........................................................................................................5 A 
Maximum breaking capacity – AC1 ............................................................................. 1250 VA 

Summary of Contents for ASW-210

Page 1: ...ASW 210 Flush mounted wireless two channel 230 V AC controller Firmware version 1 00 asw 210_en 07 19 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...e of the device is located on the enclosure base SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type ASW 210 is in compliance with Dir...

Page 3: ... the controller outputs 2 programmable wired inputs support for NO or NC type switches Encrypted two way radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission without interference with other signals in the 868 MHz frequency band ABAX 2 system only Remote update ...

Page 4: ...hase wire NO1 gray NO contact of the relay output 1 normally it is disconnected from the common contact C does not conduct electricity NO2 black NO contact of the relay output 2 normally it is disconnected from the common contact C does not conduct electricity C red common contact C of the relay outputs Terminals SW1 SW2 control input NO N for connecting 230 V AC supply neutral wire Radio communic...

Page 5: ...a risk of electric shock and may damage the module The wired inputs of the controller are not galvanically isolated It is not recommended to use the controller to switch the capacitive loads e g LED lighting power supply units LED lamps more frequently than every 10 seconds Do not connect more than one LED lighting power supply to the relay output The ASW 210 controller is designed for mounting in...

Page 6: ...e ASW 210 controller and check if it improves the signal strength The controller can be installed in the selected junction box if the signal strength is higher than 40 9 Power off the circuit to which the controller is connected 10 Open the junction box and remove the controller 11 Connect the wires of controller relay outputs to the wires of electrical circuits to be controlled by the controller ...

Page 7: ...SATEL ASW 210 5 ...