background image

SATEL ASP-100 

 

Two sound frequencies (1450 Hz/2000 Hz) alternating within 1 second 

 

Sound with rising frequency (from 1450 Hz to 2000 Hz) within 1 second 

 

Sound with smoothly rising and falling frequency (1450 Hz – 2000 Hz – 
1450 Hz) within 1 second 

 

Sound with falling frequency (from 2000 Hz to 1450 Hz) within 1 second 

 

Table 1. Tone types for acoustic signaling. 

Power supply 

The siren is powered from a 3.6 V lithium thionyl chloride battery. It is a high-current battery, 
characterized by high capacity. The battery is offered by SATEL. 

Given the specific nature of the battery, it must be properly initialized to reach the required 
performance. The battery initialization procedure starts automatically after first-time 
connection of the battery. During battery replacement, follow the procedure described at the 
end of this manual to initialize a new battery. 

When initializing a battery, the leftmost LED on the siren is blinking every second. The siren will not 
be ready for operation until the battery initialization procedure is completed. 
The siren informs about low battery. 

Periodic transmissions 

Every 15 minutes, the siren sends a transmission with information on the current status of the tamper 
switch and battery. Periodic transmissions are used to monitor presence and operation of the siren. 

Note:  If any value different from 0 is programmed for the 

F

ILTER

 parameter for the ASP-100 siren, 

the lack of presence will be reported if no transmission from the detector is received within one 
hour. 