SATALARM SA-612 & SA-816 installer manual ver 1.1
-
PGM activation/deactivation by PC
(only for PGM outputs defined as “mono-stable”, “bi-stable” or “clock timer”
types);
-
Online display of the system/partitions status and troubles
;
-
Real-time, online display of the bypassed, alarmed or open zones
.
• Programmable callback function
with up to 3 attempts, automatic or manually activation (manually activation may be
performed by master user or installer);
• 800-events LOG upload with display and save possibility
and optionally reported to CS;
• Option of automatic answer to PC calls,
either after “double call” or after programmable number of rings;
• Manual activation of communication with PC (PC upload/download acceptance),
performed by master user or installer;
• Cancellation of PC to panel communication
performed by master user or installer.
Zones
• 6/8 fully programmable zones
on the main board,
expandable to 12/16 zones using zone doubling feature or keypads’ zones
,
with
single or double EOL resistor, NO/NC contacts, tamper recognition
and programmable as delayed, instant, follower, 24
hour burglary, fire, tamper, panic, medical emergency, arming/disarming (“keyswitch” or “stay keyswitch”) or guardian round
type;
• SATALARM SA-816Pw
give installer the option of choosing how many of the 16 zones controlled by panel are wireless.
Any combination of wired and/or wireless up to 16 zones can be done.
• 17 zone attributes, individually programmable
as “
audible/silent alarm
”, “
steady/pulsing siren
”, “
manual bypassing
”, “auto
shutdown”, “
forced arming
”, “chime
function activating
”, “
stay
”, “
intellizone
”, “
sensor under test
”, as well as
individually
selectable zone response time
;
• “Zone bypassing”
(
automatic
“from swinger shut-down” or caused by home arming, if the zones have the “stay” attribute
activated -
and
manually
by the users);
• 2 real partitions which can be armed/disarmed independently from each other
– allowed by user rights;
• Individually programmable exit and entry delay times for each partition
– allowed by programming;
•
Programmable alarm type:
silent or audible and for audible alarms steady or pulsing;
•
Individual siren timers for burglary and fire alarms;
PGM functions
•
2 programmable outputs (PGMs) on the main board, expandable to 8 PGMs using other modules, each with 36 options, such
as:
“
Panic alarm latch
”
,
“
Fire alarm latch
”
,
“
Medical emergency alarm latch
”
,
“
Latch on tamper alarm
”
,
“
Any alarm latch
”
,
“Pulsing siren
”
,
“Steady siren
”
,
“silent alarm” latch
,
“
Follow system status
”
(ON while system is armed / OFF while system is
disarmed)
,
“
Entry delay
”
,
“
Exit delay
”
,
“
System troubles
”
,
“
Clock timer
”
,
“
Warning/confirmation pulses
”
,
“
Pulse after exit
delay
”
,
“
Pulse on arming
”
,
“
Pulse on disarming
”
,
“
Courtesy light
”
,
“
Pulse on siren troubles
”
,
“
Retriggerable mono-stable
”
,
“
Resetable mono-stable
”
,
“
Bi-stable
”
and
“
Pulse on alarm triggered by each 1 to 12/16 zones
”;
Monitoring of system troubles
• Battery Voltage and AC power monitoring
;
•
Siren monitoring
(upon disconnection, short circuit or overload);
•
“AUX overload” monitoring
;
• Option of telephone line monitoring (TLM).
Voice messages (synthesis sounds) Communicator
• Capability of response to the remote calls for system status interrogation
(the system status -armed/disarmed/alarm/”AC
power loss” – will be reported by specific voice messages or by specific synthesis sounds);