45
EN
Operating Instructions SATA LPS R 2000, SATA LPS RB 2000 RP, SATAminijet 1000 A S HVLP
Operating Instructions SATA LPS R 2000, SATA LPS RB 2000 RP, SATAminijet 1000 A S HVLP
12. Troubleshooting
Malfunction
Cause
Corrective Action
Unruhiger Spritz
-
strahl (Flattern /
Spucken)
Fluid tip not properly
tightened.
Tighten fluid tip with
universal spanner.
Air distribution ring
soiled or damaged.
Replace the air dis
-
tribution ring (see
chapter 9.2).
Loose air cap.
Tighten air cap ring
by hand.
Gap between air
cap and fluid tip is
clogged.
Clean gap.
Nozzle set is soiled.
Clean nozzle set.
Damaged nozzle set. Replace the nozzle
set (see chapter 9.1)
Material flow pres
-
sure not constant.
Check material flow
pressure.
Spray pattern too
small, slanted,
one-sided or split.
Air cap hole clogged
with paint.
Clean the air cap
(see chapter 9.1).
Damaged fluid tip
(fluid tip aperture).
Check the fluid tip
for damage. Replace
the nozzle set if nec
-
essary (see chapter
9.1).
The round/flat fan
control is not work
-
ing – control can be
turned.
Air distribution ring
not correctly posi
-
tioned (pin not in
hole) or damaged.
Replace the air dis
-
tribution ring (see
chapter
9.2).
Round/flat fan con
-
trol cannot be regu
-
lated.
The round/flat fan
control has been
turned counterclock
-
wise over the limit;
the spindle is loose
in the gun thread.
Unscrew the round/
flat fan control using
the universal span
-
ner and make it work
again or replace
it completely (see
chapter 9.4).
Summary of Contents for LPS R 2000
Page 6: ......
Page 28: ......
Page 48: ......
Page 93: ...7 8 7 1 7 2 8 2 8 1...
Page 94: ...9 9 3 9 2 9 1 10 10 5 10 6 10 7 10 8 10 4 10 3 10 2 10 1...
Page 95: ...11 11 5 11 4 11 3 11 2 11 1 12 12 4 12 5 12 3 12 2 12 1...
Page 97: ...1 11 1 10 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 1 1 2 1...
Page 98: ...2...