<< Operating instructions SATA filter 244/264/284 >>
<< Operating instructions SATA filter 244/264/284 >>
US
VI.7
<< US-English >>
• Unscrew intermediate adapter
[4-5]
at filter stage
[B]
and
[C]
, then
remove
[4-3]
and replace fine or activated charcoal cartridge, resp.
• Installation has to be carried out in reverse order. Please make sure
that the filter cartridges are installed in the correct order. Coloured
markers (yellow = sintered filter
[A]
, blue = fine filter
[B]
, black =
activated charcoal filter
[C]
allow clear identification
[4-4]
. Marking
rings are located on the threaded rods of the filter stages
[B]
and
[C]
,
adhesive stickers
[1-7], [1-11], [1-13]
on the filter housings.
• During installation, please ensure proper seat and undamaged O-rings!
Information!
Please observe local regulations for the disposal of filter cartridges!
11. Troubleshooting
Malfunction
Cause
Corrective action
Pressure cannot be
properly adjusted
Insufficient inlet pres-
sure
Increase inlet pressure
Pressure regulation
valve at air outlet mod-
ule is defective
Exchange pressure
regulation valve [D],
Art. No. 171496
Traces of compressor
oil in the compressed
air
Too much oil in the
compressed air
Control compressor,
refrigerated dryer
Drain condensate
(open manually)
Saturated filter
Filter maintenance
required, chapter 10
No or insufficient con-
densate drainage (a
minimum condensate
level is required as it
serves to lift the floater
and, thus, to open the
drain valve)
Floater stuck on the
drain valve
Disassemble drain
valve by removing the
safety disc, then clean
or exchange drain
valve
Damaged drain valve
Exchange drain valve
Art. No. 15511
US-SATA filter 200.indd 7
07.02.2011 13:36:55