80
EN
Operating Instructions SATA filter 500
Notice!
Activated charcoal filter cartridge:
• Sintered activated charcoal
9.4. Pressure reducer unit [D]:
The standard pressure reducer unit is equipped with 2 ball valves
[1-3]
connecting thread ¼" (male thread) and can be extended with an outlet
module. The required outlet pressure can be finely adjusted at the pres
-
sure reducing valve
[1-7]
using the regulating cap
[1-8]
and pressure
gauge
[1-6]
.
10. Maintenance
Warning! Attention!
• Filters can only be maintained and serviced when depressurised!
•
Sintered filter
[A]/Art. No. 22160,
filter housings
[1-9], [1-11],
[1-12]
and special seal
[1-16]
must be cleaned at the latest after 6
months; replace sintered filter if necessary!
•
Replace the fine filter cartridge
[B]/Art. No. 1097999
at the latest
after 6 months!
• Replace the activated charcoal cartridge
[C]/Art. No. 1098004
at
the latest after 6 months!
•
When the compressed air is heavily contaminated, the filter
cartridges have to be exchanged in shorter intervals!
• Saturated filter cartridges may cause malfunctions during paint
jobs. Furthermore, the use of air-fed breathing protection equip-
ment could be harmful, causing permanent health damage and
even death!
•
Always make sure that the filter housings are fitted correct-
ly!
Filter housings are only correctly fitted after an audible “
click”
!
Notice!
Please observe local regulations for the disposal of filter cartridges!
Summary of Contents for 500
Page 14: ......
Page 48: ......
Page 60: ......
Page 72: ......
Page 84: ......
Page 108: ......
Page 168: ......
Page 180: ......
Page 192: ......
Page 204: ......
Page 254: ......
Page 278: ......
Page 290: ......
Page 302: ......
Page 303: ... 1 SATA filter 584 1099953 A B C 1 5 1 1 1 13 1 9 1 10 1 14 1 11 1 12 1 15 1 16 A B C ...
Page 304: ... A 22160 B 1097999 C 1098004 D 1 8 1 7 1 2 1 6 1 3 1 4 D ...
Page 305: ... 2 2 1 2 2 2 3 ...
Page 306: ... 3 ...
Page 307: ... 4 ...
Page 308: ... 5 ...
Page 309: ... 15 6 ...