Setting the heating temperature limit (electrical floor heating)
Th
e receiver has an option to set the highest heating temperature when using electrical floor heating. This mode is only
available if you’re using an external floor sensor plugged in the receiver. Sensor must be NTC 100K.
To turn on this mode, you must install the floor sensor and turn on the receiver, so that LED A is lit (red). Now hold the
button for 3 seconds and LED A (red) will now turn off and start blinking green. Now, with pressing the button, you
change the LED indicators that are lit and with that
the temperature limitation.
If LED indicators are lit:
-
LED A and
LED B (
both green) : temperature limitation will be set to 30°C
-
LED A (
green) and
LED C (
yellow): temperature limitation will be set to 40°C
-
LED A (
green
), LED B (
green) and
LED C (
yellow): temperature limitation will be set to
55°C
- blinking
LED A (
green) : temperature limitation is not set
To exit and save the settings, hold the button for 3 seconds.
Connecting (pairing) the thermostat and the receiver
If you’ve purchased the receiver and the thermostat together, then they should already be paired. Follow these
instructions if that is not the case of if you need to pair them again.
Turn off the receiver, so that none of the LED indicators are lit. Now hold the button for 3 seconds, so that LED C
(yellow) will be lit. Now the receiver is ready for pairing and waiting for the thermostat.
Now, follow the instructions for pairing in the thermostat’s manual. When the pairing is complete, usually the
thermostats LCD displays “1” and the receivers LED indicator C blinks 5 times and then turns off.