32
Step
Factory
default value
Setting
options
Description
4
21.0°C
20.0°C –
25.0°C
Higher, Day mode temperature
(Comfort) – this temperature is used
when you’re using the Day mode, for example, during the day or when you’re
at home.
5
On
On / Off
Display backlight
–
If set to On, the thermostat will use display backlight. If
set to Off, the display backlight and the screen will stay dark.
6
00.0°C
-
5.0°C
–
05.0°C
Temperature display correction
–
In the event of a deviation of the actual
room temperature from the temperature shown to you by the thermostat on
the screen, you have the option of adjusting the temperature display. For
example. The temperature in the room is 20.0 ° C, the th
ermostat shows 21.0
° C. Select a value of
-1.
7
Hp
P1/Hp
Heating system control – HP
: Constant temperature. The thermostat
considers the hysteresis –
the temperature range, e.g. 0.5°C.
For example, you have a heating temperature of 22.0°C and a range of 0.5°C.
The heating system starts to operate when the room temperature drops to
21.5 °C and switches off when the temperature reaches 22.5 °C.
Pi:
PWM
module - thermostat maintains temperature with minimum
temperature ranges. Used in underfloor heating.
8
0.5°C
0.1°C –
05.0°C
Temperature range, hysteresis
-
This function is active if you have the Hp
function enabled under step 7. See description above.
9
On
On / Off
Automatic short-time switching function (circulation pump, valve) -
Option of setting the automatic activation function, for example, circulation
pumps, valves
-
this feature allows automatic activation of the circulation
pump, or valve for 30 seconds, in the event that there was no power on in
the last 24 hours.