 Intended 

Use 

Intended Use

The Sartorius TopMix2.Touch has been designed for use in paint-mixing applications. It consists of an operator 
terminal (TM02-X, monitor and touch screen) and an ex-link converter (YCO12-Z) which is installed outside the 
potentially explosive area. They are both linked together by the special 20 m cable provided.  
The TM02-X is used in potentially explosive areas. An explosion-protected, intrinsically safe scale can be 
connected to the TM02-X. The intrinsically safe TopMix2.Touch keyboard YKB01TM-X may optionally be 
connected to the TM02-X terminal/control panel.

A PC may be connected to the ex-link converter (YCO12-Z) outside the potentially explosive area using a DVI 
video and USB cable.  
The scale connected to the TM02-X can be controlled by the user's software installed on the PC.

The process data are visible on the TM02-X DVI display at all times during mixing. A test monitor may also be 
connected to the ex-link converter (YCO12-Z) outside the potentially explosive area.

Make sure to read and store these installation instructions carefully before installing and operating your 
TopMix paint-mixing weighing system. 

 
The TM02-X terminal/control panel may not be used as a standard office PC. 

Safety Precautions

Legal Information

This device meets stipulated safety requirements. Improper use or handling, however, can result in damage 
and/or injury.  
The manufacturer is not responsible for any damage caused by non-compliance with warnings or safety 
instructions. 

–  

The requirements pertaining to applicable installation regulations must be followed when using electrical 
equipment in systems and environmental conditions with increased safety requirements. 

The use of the terminal/control panel and the ex-link converter (YCO12-Z) is not permitted in legal metrology 
or in medical areas or potentially explosive areas containing dust or explosive materials. 
 

–  

The intrinsically safe terminal/control panel and the ex-link converter (YCO12-Z) have been manufactured in 
accordance international standards (see certificates in the appendix). 
The TopMix can be operated with intrinsically safe Sartorius scales in the hazardous area/location, e.g.: 
PMA7501-X (see: “Verification of Intrinsic Safety", drawing number 36942-751-60, for ATEX and “Control 
drawing”, drawing number 36942-751-07, for Canada and the USA).

Summary of Contents for TopMix2.Touch TM02-X

Page 1: ...Operating Instructions Sartorius TopMix2 Touch Model TM02 X Paint mixing terminal control panel for potentially explosive areas 98648 019 41...

Page 2: ...g System 10 Making the Connections 10 Installing the Ex Link Converter YCO12 Z 11 Power Connection 12 Care and Maintenance 13 Service 13 Repairs 13 Safety Inspections 13 Cleaning 13 Corrosive Environm...

Page 3: ...ter 7 Connector for the power cord supply voltages from 90 to 264 VAC 8 LEDs 9 Interface 10 Connection between the ex link converter and a standard PC outside the potentially explosive area Connector...

Page 4: ...anual from our website www sartorius com Warning Danger Symbols Warning danger symbols used in these instructions This symbol identi es hazards which have a high probability of resulting in death or s...

Page 5: ...tallation instructions carefully before installing and operating your TopMix paint mixing weighing system The TM02 X terminal control panel may not be used as a standard of ce PC Safety Precautions Le...

Page 6: ...on and safety by a trained and quali ed person at appropriate intervals e g checking the cable for damage Operating personnel must be trained to recognize faulty operating states and to be able to ini...

Page 7: ...o be installed exclusively in locations that offer suf cient protection against the penetration of solid foreign bodies or water The safety of the equipment is compromised by foreign bodies and water...

Page 8: ...entially explosive area length 3 m D SUB 9 pin cable YCC01 0041M3 to connect a scale length 3 m Power supply cable for the ex link converter 3 Grounding cables YCC01 X046M2 Installation instructions B...

Page 9: ...cording to commonly accepted technical standards Only cables and cable lengths approved by Sartorius should be used which take account of the limitations of the cable lengths due to the capacity and i...

Page 10: ...f a quali ed electrician to ensure that the system is in good working order Check whether or not the competent authorities e g industrial supervisory board need to be informed It is also necessary to...

Page 11: ...CC01 0049M20 length 20 m into the ex link converter YCO12 Z Ex side Tighten the safety screws firmly 5 USB port Insert TopMix PC USB cable YCC01 0040M3 for connecting a standard PC to the ex link conv...

Page 12: ...operating the TopMix TM02 X in potentially explosive areas follow the current standards and regulations for the installation of devices in hazardous areas locations Switching the TopMix Weighing Syst...

Page 13: ...relatively long period under unfavorable conditions In this case notify the Sartorius Service Center Maintenance and repair work may only be performed by authorized service technicians who have access...

Page 14: ...enance Do not apply any cleaning agents to ID labels or printed surfaces Corrosive Environment t Remove all traces of corrosive substances from the device on a regular basis Storage and Shipping Condi...

Page 15: ...http www sartorius com 2 Select the Services tab 3 Then select Disposal Information 4 Addresses for the local Sartorius disposal contacts can be found in the PDF files available for download on this p...

Page 16: ...xplosive areas in accordance with Directive 94 9 EC category 2 equipment IP protection rating IP 40 as per EN 60529 IEC60529 Ambient Conditions Environment For indoor use only Ambient temperature Stor...

Page 17: ...xplosive areas TM02 X Ex link converter YCO12 Z Keyboard for use in Zone 1 potentially explosive areas YKB01TM X Ex link cable 20 m YCC01 0049M20 Video cable DVI 3 m YCC01 0050M3 USB cable 3 m YCC01 0...

Page 18: ...18 Operating Instructions TopMix Scale Drawings Dimensions Scale Drawings Dimensions Table Top Use Wall Mounting Drilling template Dimensions in millimeters...

Page 19: ...Operating Instructions TopMix 19 EC Declaration of Conformity...

Page 20: ...20 Operating Instructions TopMix EC Declaration of Conformity...

Page 21: ...Operating Instructions TopMix 21 EC Declaration of Conformity...

Page 22: ...connected to the terminal for the equipotential bonding conductor PA The equipment operator is obligated to connect a lead with a gauge of at least 4 mm cross section to the PA terminal located on th...

Page 23: ...02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2V Uo 8 4 V 16 8V Ii 131 mA Io 85 mA Pi any Po 179 mW Ci 11 nF Co 9 0 F 0 9 F Li 0 mH Lo 1 mH 2 2 Keyboard Option YKB01TM X II...

Page 24: ...G Ex ib IIB Gb Terminal TM02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2V Uo 8 4 V 16 8V Ii 131 mA Io 85 mA Pi any Po 179 mW Ci 11 nF Co 9 0 F 0 9 F Li 0 mH Lo 1 mH 2 2 Key...

Page 25: ...ta cable e g LiYCY with 400nF km and 2mH km functionally limited 20m Ex Link Converter YCO12 Z II 2 G Ex ib IIB Gb Terminal TM02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2...

Page 26: ...ith Entity Concept parameters 10 appropriate for connection to associated apparatus with Entity Concept parameters listed in note 4 12 pole round connector 2 Video out 2 USB SARTORIUS Model PMA7501 X...

Page 27: ...i Pi of the intrinsically safe apparatus and the approved values of Ca and La resp Co and Lo of the associated apparatus are greater than Ci and Li of the intrinsically safe apparatus plus all cable p...

Page 28: ...28 Operating Instructions TopMix EC Type Examination...

Page 29: ...Operating Instructions TopMix 29 EC Type Examination...

Page 30: ...30 Operating Instructions TopMix EC Type Examination...

Page 31: ...Operating Instructions TopMix 31 EC Type Examination...

Page 32: ...32 Operating Instructions TopMix IECEx Cerfificate of Conformity...

Page 33: ...Operating Instructions TopMix 33 IECEx Cerfificate of Conformity...

Page 34: ...34 Operating Instructions TopMix IECEx Cerfificate of Conformity...

Page 35: ...Operating Instructions TopMix 35 Certificate of Compliance...

Page 36: ...36 Operating Instructions TopMix Certificate of Compliance...

Page 37: ...Operating Instructions TopMix 37 Certificate of Compliance...

Page 38: ...38 Operating Instructions TopMix Certificate of Compliance...

Page 39: ...Operating Instructions TopMix 39 Certificate of Compliance...

Page 40: ...40 Operating Instructions TopMix Certificate of Compliance...

Page 41: ...eans without prior written permission from Sartorius All rights reserved The status of the information specifi cations and illustrations in this manual is indicated by the date given below Sartorius r...

Reviews: