Sartorius TopMix2.Touch TM02-X Operating Instructions Manual Download Page 16

16

 Operating 

Instructions 

TopMix

  Specifications

Specifications

TopMix TM02-X with Ex-link Converter (YCO12-Z)

Model  

TM02-X

Permitted operating/ambient temperature  °C 

+0 to +40

Housing measurements (W 

 D 

 H)   

TopMix control unit 

mm 

420 

 315 

 332 (with bracket)

Ex-link converter (W 

 D 

 H) 

mm 

320 

 240 

 71

Net weight,  TopMix control unit, approx. 

kg 

ex-link converter, approx. 

kg 

bracket kg 

1.5 

ex-link cable 

kg 

1.5

Power connection 

100 – 240 V ~

Frequency 

Hz 

50 – 60

Power consumption (typ.) 

VA 

25

Device ID [explosion protection] 
Terminal/control panel TM02-X 

 

II 2G Ex ib mb IIB T4 Gb DEKRA 12ATEX0246 X) 

Ex-link converter YCO12-Z 

 

II (2)G [Ex ib Gb]IIB DEKRA 12ATEX0246 X)

The terminal/control panel is suitable for  
use in Zone 1 potentially explosive areas  
in accordance with Directive 94/9/EC  
(category 2 equipment).

IP protection rating 

 

IP 40 (as per EN 60529/IEC60529)

Ambient Conditions

Environment 

 

For indoor use only

Ambient temperature: Storage and transport  

–10°C to +60°C

Ambient temperature: Operation 

 

0°C to +40°C

Maximum relative humidity 

 

 80% for temperatures up to 31°C, decreasing linearly up to 50% relative 
humidity at 40°C

Safety of Electrical Equipment

 

 

 In accordance with EN 61010-1:2010  
Safety requirements for electrical equipment for measurement, control, and 
laboratory use – Part 1: General requirements

Electromagnetic Compatibility

 

 

In accordance with EN 61326-1:2006  

 

 

Electrical equipment for measurement, control, and laboratory use  

 

 

EMC requirements – Part 1: General requirements 

Defined immunity to interference: 

 

Industrial areas 

Emissions:  

 

Class B: Suitable for use in residential areas and areas that are directly 
connected to a low voltage network

Summary of Contents for TopMix2.Touch TM02-X

Page 1: ...Operating Instructions Sartorius TopMix2 Touch Model TM02 X Paint mixing terminal control panel for potentially explosive areas 98648 019 41...

Page 2: ...g System 10 Making the Connections 10 Installing the Ex Link Converter YCO12 Z 11 Power Connection 12 Care and Maintenance 13 Service 13 Repairs 13 Safety Inspections 13 Cleaning 13 Corrosive Environm...

Page 3: ...ter 7 Connector for the power cord supply voltages from 90 to 264 VAC 8 LEDs 9 Interface 10 Connection between the ex link converter and a standard PC outside the potentially explosive area Connector...

Page 4: ...anual from our website www sartorius com Warning Danger Symbols Warning danger symbols used in these instructions This symbol identi es hazards which have a high probability of resulting in death or s...

Page 5: ...tallation instructions carefully before installing and operating your TopMix paint mixing weighing system The TM02 X terminal control panel may not be used as a standard of ce PC Safety Precautions Le...

Page 6: ...on and safety by a trained and quali ed person at appropriate intervals e g checking the cable for damage Operating personnel must be trained to recognize faulty operating states and to be able to ini...

Page 7: ...o be installed exclusively in locations that offer suf cient protection against the penetration of solid foreign bodies or water The safety of the equipment is compromised by foreign bodies and water...

Page 8: ...entially explosive area length 3 m D SUB 9 pin cable YCC01 0041M3 to connect a scale length 3 m Power supply cable for the ex link converter 3 Grounding cables YCC01 X046M2 Installation instructions B...

Page 9: ...cording to commonly accepted technical standards Only cables and cable lengths approved by Sartorius should be used which take account of the limitations of the cable lengths due to the capacity and i...

Page 10: ...f a quali ed electrician to ensure that the system is in good working order Check whether or not the competent authorities e g industrial supervisory board need to be informed It is also necessary to...

Page 11: ...CC01 0049M20 length 20 m into the ex link converter YCO12 Z Ex side Tighten the safety screws firmly 5 USB port Insert TopMix PC USB cable YCC01 0040M3 for connecting a standard PC to the ex link conv...

Page 12: ...operating the TopMix TM02 X in potentially explosive areas follow the current standards and regulations for the installation of devices in hazardous areas locations Switching the TopMix Weighing Syst...

Page 13: ...relatively long period under unfavorable conditions In this case notify the Sartorius Service Center Maintenance and repair work may only be performed by authorized service technicians who have access...

Page 14: ...enance Do not apply any cleaning agents to ID labels or printed surfaces Corrosive Environment t Remove all traces of corrosive substances from the device on a regular basis Storage and Shipping Condi...

Page 15: ...http www sartorius com 2 Select the Services tab 3 Then select Disposal Information 4 Addresses for the local Sartorius disposal contacts can be found in the PDF files available for download on this p...

Page 16: ...xplosive areas in accordance with Directive 94 9 EC category 2 equipment IP protection rating IP 40 as per EN 60529 IEC60529 Ambient Conditions Environment For indoor use only Ambient temperature Stor...

Page 17: ...xplosive areas TM02 X Ex link converter YCO12 Z Keyboard for use in Zone 1 potentially explosive areas YKB01TM X Ex link cable 20 m YCC01 0049M20 Video cable DVI 3 m YCC01 0050M3 USB cable 3 m YCC01 0...

Page 18: ...18 Operating Instructions TopMix Scale Drawings Dimensions Scale Drawings Dimensions Table Top Use Wall Mounting Drilling template Dimensions in millimeters...

Page 19: ...Operating Instructions TopMix 19 EC Declaration of Conformity...

Page 20: ...20 Operating Instructions TopMix EC Declaration of Conformity...

Page 21: ...Operating Instructions TopMix 21 EC Declaration of Conformity...

Page 22: ...connected to the terminal for the equipotential bonding conductor PA The equipment operator is obligated to connect a lead with a gauge of at least 4 mm cross section to the PA terminal located on th...

Page 23: ...02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2V Uo 8 4 V 16 8V Ii 131 mA Io 85 mA Pi any Po 179 mW Ci 11 nF Co 9 0 F 0 9 F Li 0 mH Lo 1 mH 2 2 Keyboard Option YKB01TM X II...

Page 24: ...G Ex ib IIB Gb Terminal TM02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2V Uo 8 4 V 16 8V Ii 131 mA Io 85 mA Pi any Po 179 mW Ci 11 nF Co 9 0 F 0 9 F Li 0 mH Lo 1 mH 2 2 Key...

Page 25: ...ta cable e g LiYCY with 400nF km and 2mH km functionally limited 20m Ex Link Converter YCO12 Z II 2 G Ex ib IIB Gb Terminal TM02 X II 2G Ex ib mb IIB T4 Gb RS232 Data Output Interface 3 Ui 12 6 V 25 2...

Page 26: ...ith Entity Concept parameters 10 appropriate for connection to associated apparatus with Entity Concept parameters listed in note 4 12 pole round connector 2 Video out 2 USB SARTORIUS Model PMA7501 X...

Page 27: ...i Pi of the intrinsically safe apparatus and the approved values of Ca and La resp Co and Lo of the associated apparatus are greater than Ci and Li of the intrinsically safe apparatus plus all cable p...

Page 28: ...28 Operating Instructions TopMix EC Type Examination...

Page 29: ...Operating Instructions TopMix 29 EC Type Examination...

Page 30: ...30 Operating Instructions TopMix EC Type Examination...

Page 31: ...Operating Instructions TopMix 31 EC Type Examination...

Page 32: ...32 Operating Instructions TopMix IECEx Cerfificate of Conformity...

Page 33: ...Operating Instructions TopMix 33 IECEx Cerfificate of Conformity...

Page 34: ...34 Operating Instructions TopMix IECEx Cerfificate of Conformity...

Page 35: ...Operating Instructions TopMix 35 Certificate of Compliance...

Page 36: ...36 Operating Instructions TopMix Certificate of Compliance...

Page 37: ...Operating Instructions TopMix 37 Certificate of Compliance...

Page 38: ...38 Operating Instructions TopMix Certificate of Compliance...

Page 39: ...Operating Instructions TopMix 39 Certificate of Compliance...

Page 40: ...40 Operating Instructions TopMix Certificate of Compliance...

Page 41: ...eans without prior written permission from Sartorius All rights reserved The status of the information specifi cations and illustrations in this manual is indicated by the date given below Sartorius r...

Reviews: