Fault
Possible Cause
Proposed Fix
Generator being used
‘The Reverse Polarity warning light is on when using my
Generator’.
This is a normal side effect when using some types of generator.
Instead of connecting the neutral conductor to earth, some
generators centre tap the earth connection making both neutral and
live conductors 110V above earth. This 110V difference causes the
neon polarity indicator to illuminate. In most cases it is still safe to
use the generator, but please consult the generator handbook for
further information.
Control Panel
Problems
Control Panel has no
display
Check batteries and fuses, turn PSU isolate switch and charger
switch on and ensure mains supply is connected.
Check control panel connecting lead at PSU and behind Control
Panel.
Contact your Dealer.
12V Power turns off
Battery protect feature has operated to protect the Vehicle battery
and or the Leisure battery. See 3.4C
Over voltage protection has been activated, the control panel will
display a warning. A number of things can cause this but the most
common is the solar panel, it is worth checking the regulator is
connected correctly and operating within the correct parameters.
Engine has been started, all equipment has been disconnected to
meet EMC requirements. See 2.6
Control Panel locked /
erratic function
Observe control panel handling instructions.
Control panel software may have crashed. Reboot control panel by
turning off the PSU isolate switch. Wait 30 seconds then turn the
switch back on. Check with your dealer that your system has the
latest software installed, as an update may be available.
No 12 volt output
from PSU
No 230V supply
Check all above.
Charger not switched on
Turn charger switch on, switch will illuminate.
Battery not connected
and / or charged
Install charged battery as per 3.4
Power button on control
panel not switched to on
Turn power on at control panel.
Battery flat / Battery fuse
blown
Recharge battery, check fuses, check charging voltage is present at
battery.
Fuse blown
Check all fuses are intact and the correct value fuse is installed as
per fuse table.
Equipment switched off /
unplugged
Check equipment is switched on and connected to the 12V supply.
Other fault
Contact your Dealer.
Pump not
working
Fuse blown
Replace fuse with correct value as per fuse table.
Pump turned off
Turn pump on by pressing the pump button at the control panel.
Lights not
working
Fuse/s blown
Replace fuse with correct value as per fuse table.
Lights turned off
Turn Lights on by pressing the lights button, use dimmer at the
control panel.