background image

 
 

EC700 Power Control System 

 

Issue: 1 

Page 14 of 17 

1

st

 October 2017 

With control panel power on and 
leisure battery selected (as active 
battery) and the voltage level is below 
9V 

Message on screen and 60 second 
audible beep.  If no action taken after 
30 seconds then the system will 
switch the power off to prevent 
severe discharge of the battery 

Note: This is an emergency cut off level to protect the battery from severe 
damage.  You should not rely on this cut off level during normal operation, but 
manage your power consumption to a discharge level of 11.5V or above. 
This cut off only applies to power drawn from the battery by the leisure 
equipment that is controlled by the control panel power switch; it will not protect 
the battery from discharge by permanently connected equipment. 

Leisure battery voltage 
high 

With control panel power on or off and 
leisure battery is selected (as active 
battery) and the voltage level rises 
above 15V 

Message on screen and repeated 
beeps from the control panel.  The 
power is automatically turned off. The 
beeping will not stop until the fault is 
cleared. 

Vehicle battery 
warnings 

If the vehicle battery is selected instead of the leisure battery, then similar 
warnings to those described above are applied to the vehicle battery.  The 
vehicle battery low warning level is 10.9V 

Engine running 

When the engine is started the system 
power will be turned off 

Message on screen, Leisure & 
Vehicle battery symbols indicating 
both batteries are connected for 
charging.  The charging voltage is 
also shown on screen. 

Step extended 

Step extended and engine started 

Message on screen and warning 
buzzer 

Step jammed or obstructed 

Mains lead (hook-up 
cable) still connected / 
plugged in 

When the engine is started and the 
mains cable is still plugged in and the 
charger is switched on 

Message on screen and repeated 
beeps from the control panel.  The 
beeping will not stop until the hook-
up lead is removed. 

 

3.14  Common Fault Table 

Fault 

Possible Cause 

Proposed Fix 

No 230 volt 

output from PSU 

Connecting lead between 
the site and Leisure 
Vehicle not connected 

Check and connect lead as per 2.3C 
 

RCD switched off 

Reset RCD as per 2.3D 

RCD not operating 
correctly 

Check supply polarity; if the RCD continues to fail contact your 
Dealer as there is probably an equipment or wiring fault. 

MCB switched off 

Reset MCB by switching OFF (down position) then back ON (up 
position), if the MCB continues to fail contact your Dealer as there 
is probably an equipment or wiring fault. 

No or deficient supply 
from site 

Contact site Warden for assistance. 

Other fault 

Contact your Dealer.  

Reverse Polarity 

light is 

illuminated on 

PSU 

Mains Supply reversed? 

The reverse polarity light is designed to illuminate when the Live 
and Neutral supply has been reversed / crossed over. If the light 
illuminates there is a problem with the site supply or the cable 
connecting the supply to your vehicle. The light is designed to work 
on UK electrical supplies (where the neutral conductor is connected 
to earth at the substation). If you are using your vehicle outside the 
UK this light may illuminate when no fault exists. In these cases 
consult the site warden for advice. 

Summary of Contents for EC700

Page 1: ...forward controls and reliable data communication to the PSU The PX300 Intelligent Battery charger 300W A separate air cooled 300 Watt multi stage power converter unit that charges the batteries and provides 12V DC power The EM40 Vehicle Interface Unit This small unit is located at floor level behind the drivers seat The unit houses fuses for the fridge vehicle battery radio and other systems It al...

Page 2: ...upply D Check Residual Current Device operation Locate the RCD within the PSU and ensure the RCD is switched on lever in up position Press the Test button and confirm that the RCD turns off lever in down position Switch the RCD back to the on position lever in up position If the test button failed to operate the RCD see section 3 18 E Check Miniature Circuit Breakers Locate the MCB s within the PS...

Page 3: ...t ac current and solar current Main Lights Pressing this button toggles the mains light on and off When on the button will be back lit blue Awning lights Pressing this button toggles the awning entry lights on and off When on the button will be back lit blue Dimmed Lights Pressing this button toggles the dimmed lights on and off Pressing and holding the dimmed lights button will change the dimming...

Page 4: ...C 2 5 2 Water levels screen The fresh water level is shown on the left of the screen whilst the waste water level is shown on the right Please Note that the levels on the screen will update more frequently if the pumps are switched on An audible warning will sound for up to 60 seconds and a warning message will display on screen if the fresh water level falls below 25 or if the waste is full Press...

Page 5: ...power settings screen section 2 5 4 The active battery current shows if the battery is being charged or discharged On the screen shown above the battery is being charged as the current is on the positive scale If the battery was being discharged the current would be shown on the negative scale 2 5 4 Power settings screen Settings screen navigation Left arrow takes you to the previous settings scre...

Page 6: ...s will only be on while the external temperature is below 2oC and if there is over 25 of water in the tank Active battery select The battery highlighted in blue is the active battery this is the battery being charged by mains when plugged in and the battery that is being used by the system Pressing the smart battery charging button switches smart charging on and off the button is lit blue while on...

Page 7: ...ep off and on Water level alarms pressing the water level alarm toggle button switches the water level alarms on and off Screen back light level pressing the button decreases the back light brightness while pressing the button increases the brightness Screen time out pressing the button decreases the screen time out time while pressing the button increases the screen time out time 2 5 7 Time date ...

Page 8: ...Residual Current Device RCD is basically provided to protect the user from lethal electric shock The RCD will turn off trip if the current flowing in the live conductor does not fully return down the neutral conductor i e some current is passing through a person down to earth or through a faulty appliance To ensure the RCD is working correctly the test button should be operated each time the vehic...

Page 9: ...st cases it is safe to use a generator but please consult the generator handbook for further information 3 3 Battery Charger The system incorporates an intelligent three stage battery charger During stage 1 the battery voltage is increased gradually while the current is limited to start the charging process and protect the battery At stage 2 the voltage rises to 14 4V to deliver the bulk charge to...

Page 10: ...is fuse could be up to 40A however if two batteries are fitted each battery should be fused at a maximum of 20A B Installation Removal Always disconnect the 230V mains supply and turn the PSU green charger switch to the off position button out before removing or installing the battery When connecting the battery ensure that the correct polarity is observed black is negative and red is positive and...

Page 11: ...the control panel power switch it will not protect the battery from discharge by permanently connected equipment 3 5 12 Volt DC Fuses WARNING When replacing fuses always replace a fuse with the correct value NEVER replace with a higher value rating as this could damage the wiring harness If a replacement fuse blows do not keep replacing the fuse as you could damage the wiring harness Please invest...

Page 12: ...ically adjusts and directs the charger power and solar power if a solar panel is installed to maintain the leisure and vehicle batteries at an optimal level 3 8 Water Pump Operation The EC700 control panel pump button operates the internal water pump drawing water from an internal tank if fitted or an external container when no internal tank is fitted The water tanks fresh waste incorporate a leve...

Page 13: ...is started the step will move in automatically after a short warning buzzer If this operation fails due to an obstacle a buzzer will sound continuously to warn that the step is still out and therefore requires your attention 3 12 Temperature Readings The EC700 Temperature sensor measures the core temperature of the vehicle and provides a figure for information only The same sensor also measures hu...

Page 14: ...ected for charging The charging voltage is also shown on screen Step extended Step extended and engine started Message on screen and warning buzzer Step jammed or obstructed Mains lead hook up cable still connected plugged in When the engine is started and the mains cable is still plugged in and the charger is switched on Message on screen and repeated beeps from the control panel The beeping will...

Page 15: ...nel locked erratic function Observe control panel handling instructions Control panel software may have crashed Reboot control panel by turning off the PSU isolate switch Wait 30 seconds then turn the switch back on Check with your dealer that your system has the latest software installed as an update may be available No 12 volt output from PSU No 230V supply Check all above Charger not switched o...

Page 16: ...gory 6 approved provides European coverage and is ready for use all you need to do is purchase a tracking subscription by visiting the My Auto Trail section of the Auto Trail website The tracker may reduce your annual insurance premiums and provides extra peace of mind for just 95 per year 4 4 Replacement parts The Control panel contains a small lithium battery to maintain the clock when no other ...

Page 17: ...7 x 14mm Weight 80g 5 2 Approvals System BSEN 1648 1 BSEN1648 2 compliant BS7671 2008 compliant Residual Current Device RCD 40A 30mA trip to BS EN 61008 Miniature Circuit Breakers MCB s type C 6000A breaking capacity to BSEN 60898 Electro Magnetic Compatibility EMC directive 2014 30 EU Integrated Charger BS EN 60335 1 2 29 2006 95EC IEC61000 3 2 3 1995 1 Low Voltage Directive 2006 95EC TUV 014900 ...

Reviews: