3 - INSTALLATION
3.1 - LOCATION
• Protection index of the unit: IP 21.
• Select the location for the unit on the basis of the following criteria:
- the unit must be installed in a sheltered location,
- the unit must not be installed near the following:
. sources of heat,
. combustible materials,
. return / air intake of an adjacent building.
- it is necessary to make sure that the free space around the unit is
provided (see the minimum dimensions on the drawing opposite),
- installation must be simple and make maintenance work easy,
- the unit must be secured to a wall able to support its weight.
3.2 - MOUNTING THE UNIT
• Remove the cover from the unit:
- remove the retaining screws (1 on each side and 1 on top) (
1
).
• Slide the cover upward (
2
), until the bottom edge of the covers is aligned
with the lower part of the rear support, then pull it towards you (
3
).
• Secure the unit to the wall. Refer to the position of the 4
mounting holes in the diagram opposite.
Use anchors and screws (not included) that are adapted
to the weight of the unit and the type of wall.
- Install the 2 screws in place in the upper holes (
A
) in
the wall.
- Hook the unit in place.
- Install the 2 screws in place in the lower holes (
B
).
0.80 m
0.20 m
0.20 m
1 m
3
A
B
800 mm
460
mm
360
mm
Minimum clearance in front of the unit: 1 m
1
1
1
2
Align the bottom edge of the cover with the
lower part of the rear support