4-3 Electrical wiring connections to heat pump unit
<
SHP-C90GEN : POWER SUPPLY 230V ~
>
Connect the heat pump unit and tank unit as follows.
(1) Be absolutely sure to connect the L1, N terminals on the tank unit with its respective terminal
(1) Remove the two screws of the wiring clamp (in both place).
on the HP unit (L1-L1, N-N).
(2) Connect the COM terminals on the tank unit and on the heat pump unit using a 1-conductor cable.
(2) Following the figure on the right connect the cables to the
terminals block. First crimp Ring Terminals onto the ends
of the cables, and then connect them.
(3) Secure the 2 wires for the Power Supply using the wiring
clamp on the left, and secure the COM wire and grounding
wire using the wiring clamp on the right.
Secure the wires where the cables are covered.
(3) Use Ring Terminals to do the power cable connection.
<Terminal block connections>
4-4 Grounding work
• Be absolutely sure to ground the tank unit and heat pump unit from their respective terminal block.
• Do not ground the tank unit and HP unit to a water pipe or gas pipe and do not use other appliances'
ground.
L1
N
N
terminal block of Tank
POWER SUPPLY
230V
~
terminal block of HP
L1
N
L1
wiring clamp
C
COM
Summary of Contents for SHP-C90GDN
Page 18: ... 18 07 The structure of the menus ...
Page 24: ... 24 ...
Page 36: ... 36 0HDVXUHPHQWV With packaging 1 5 7 4 6 3 0 5 9 6 17 3 6 7 6 7 7 0 0 ...
Page 48: ... 48 OHFWULFDO ZLULQJ GLDJUDP 㧨㧿㧴㧼㧙㧥㧜㧳㧰㧺㧙㧿㨃㧪 ...
Page 49: ... 49 㧨㧿㧴㧼㧙㧥㧜㧳㧴㧺㧙㧿㨃㧪 ...
Page 50: ... 50 㧨㧿㧴㧼㧙㧥㧜㧳㧱㧺㧙㧿㨃㧪 ...
Page 51: ... 51 㧨㧿㧴㧼㧙㧯㧥㧜㧳㧰㧺㧦400V 3N㨪㧪 ...
Page 52: ... 52 㧨㧿㧴㧼㧙㧯㧥㧜㧳㧱㧺㧦230V 1N㨪㧪 ...
Page 68: ... 68 Parts List SHP TH90GDN SW SHP TH90GEN SW SHP TH90GHN SW ...