After de-energized, the air-conditioner can run according to the memory contents if it is energized again.
If the timer function is not set in the last remote control, the air-conditioner will run according to the last remote
control.
If the timer function is set in the last control before it is de-energized, the air-conditioner will memorize the last
timer setting. The setting is recalculated since the energization of the air-conditioner.
If the timer function is set in the last control and the setting is reached before the air-conditioner is de-energized,
the air-conditioner will run according to the previous running mode after it is energized again.
But the timer function will terminate. The clock will not be memorized.
Memory Contents : mode, up and down swing, light, set temperature, setting fan speed, general
timer (not clock), Fahrenheit / Celsius
7-1-10. Auto-restart Function
In cooling and heating mode (not available in auto, dehumidify and fan mode), press the Turbo button, the fan
speed displayed super high speed in the remote controller and the indoor fan rotates at super high speed.
7-1-11. Turbo Function
NOTE
28