6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
SAP-KRV9AEH
Outdoor Unit
SAP-CRV9AEH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.16
Power input
W
4
8
3.94
752
Fan Motor + Compressor
230V Single-phase 50Hz
4.44
922
Rating conditions:
Indoor air temperature:
27 °C D.B. / 19 °C W.B.
Outdoor air temperature:
35 °C D.B.
Rating conditions:
Indoor air temperature
20 °C D.B.
Outdoor air temperature
7 °C D.B. / 6 °C W.B.
Heating
Cooling
4.1
800
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Performance at
Rating conditions
Running amp.
A
0.16
Power input
W
4
8
4.6
970
Indoor Unit
SAP-KRV12AEH
Outdoor Unit
SAP-CRV12AEH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor + Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.16
Power input
W
49
5.04
1,051
Fan Motor + Compressor
230V Single-phase 50Hz
5.34
1,086
Rating conditions:
Indoor air temperature:
27 °C D.B. / 19 °C W.B.
Outdoor air temperature:
35 °C D.B.
Rating conditions:
Indoor air temperature
20 °C D.B.
Outdoor air temperature
7 °C D.B. / 6 °C W.B.
Heating
Cooling
5.2
1,100
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Performance at
Rating conditions
Running amp.
A
0.16
Power input
W
49
5.5
1,135
20