2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit
SAP-KRV96EHDS
Outdoor Unit
SAP-CRV96EHDS
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling: Indoor air temperature
27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature 35
°
C D.B. / 24
°
C W.B.
Heating: Indoor air temperature
20
°
C D.B.
Outdoor air temperature 7
°
C D.B. / 6
°
C W.B.
Vertical
dB-A
dB-A
Indoor : Hi/Me/Lo/Qt*
Outdoor : Hi
Air Filter
Compressor
Refrigerant / Amount charged at shipment
g
Refrigerant Control
( 0.9 to 4.9 )
( 3,100 to 16,700 )
3.26
630
( 1.29 to 5.38 )
( 250 to 1,040 )
4.03
835
( 1.21 to 6.76 )
( 250 to 1,400 )
2.65
9,000
3.60
11,900
( 0.9 to 3.6 )
( 3,100 to 12,200 )
Shipping Volume
Cooling
Heating
480
1.6
Cooling
Heating
Depth
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Width
mm
kg
kg
m
3
mm
mm
mm
mm
230V
mm
500
-
198 to 264
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Height
Operation Sound
Electrical Rating
Air Circulation (High)
Moisture Removal (High)
W
Power Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tube Kit / Accessories
Narrow tube
Wide tube
Refrigerant
mm (in.)
Tube Diameter
mm (in.)
0.21
38.0
325
9.5
367
36.0
11.5
0.06
619
931
789
180
790
265
239
862
Outdoor Unit
Indoor Unit
265
565
6.35 (1/4)
9.52 (3/8)
m
Max. allowable tubing length at shipment
Flare Type
7.5
41 / 35 / 28 / 22
41 / 35 / 28 / 22
46
45
R410A / 1,200
Electric Expansion Valve
Washable, Anti-Mold
DC Rotary (Inverter)
Manual
Auto
Timer
Indoor / Outdoor
Fan Speeds
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps / Auto (Hi, Me, Lo)
Airflow Direction (Indoor)
Horizontal
Controls / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
C.O.P.
Compressor Locked Rotor Amperes
W/W
Optional / Air Clean Filter
kW
Performance
-
4.31
%
Power Factor
84
90
A
8.5
Power Source
Voltage Rating
Liters/h
BTU/h
Capacity
m
3
/h
220 to 240V Single-Phase 50Hz
E.E.R.
W/W
4.21
-
6