Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 20A
CB-CRV96EHDS
2-2-2. Outdoor Unit
Outdoor Unit
SAP-CRV96EHDS
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
CC
-
Micro F
VAC
External Finish
Acrylic baked-on enamel finish
FV50S ... 350
-
Yes
-
Internal Controller
Yes
Aluminum Plate Fin / Copper Tube
2
1.4
Face Area
m
2
0.414
Coil
Rows
Fin Pitch
mm
Heat Exchanger Coil
ARW35A8P60SY ... 1
Compressor Oil ... Amount
8
60
750 / 750
Ohm
DC Motor
Type
Compressor Model / Nominal Output
Compressor
Coil Resistance (Ambient Temp. 20
°
C)
Ohm
DC Rotary (Hermetic)
C-1RVN68H0K / 675W
R - S : 0.632
S - T : 0.632
T - R : 0.632
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Operation cut-off control in abnormal ambient Temp.
Safety Device
Micro F
VAC
Run Capacitor
Crankcase Heater
Yes
Yes
Yes
-
-
-
1 ... D400
Fan
Propeller
Q'ty ... Dia.
mm
Type
Type
Over- Current Protection
Over- Heat Protection
(Ambient Temp. 20
°
C)
Fan Motor
Nominal Output
Coil Resistance
Safety Device
Rough Measure RPM (Cool / Heat)
Run Capacitor
Type
Model ... Q'ty
No. of Poles
W
10