12
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit
SAP – K30
3
A
Outdoor Unit
SAP – C30
3
A
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
240V Single phase 50Hz
Rating Conditions
Running Amps.
A
0.330
0.660
12.
2
1
13.
2
Power Input
kW
0.072
0.146
2.
93
2
3.1
5
Full Load Conditions Running Amps.
A
0.330
0.660
14.51
15.5
Power Input
kW
0.072
0.146
3.472
3.69
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.