3
2-2. Major Component Specifications
2-2-1. Indoor Unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No.
POW – K301A
Controls
Microprocessor
Control circuit fuse
250 V – 3.15 A
Remote Control Unit
RCS –
4
S4E–G
Type
Cross-flow
Q´ty ... Dia. and length
mm
1 ... ø100 / L847.4
Fan motor model ... Q´ty
KFG4X–31B5P–
C
... 1
No. of poles .... rpm (240V, High)
4 ... 1,270
Nominal output
W
30
Coil resistance (Ambient temp. 20°C)
Ω
WHT – BRN : 103.3
WHT – VLT : 32.5
VLT – ORG : 75.5
ORG – YEL : 28.6
YEL – BLK : 18.9
BLK – PNK : 48.0
– :
–
– :
–
Safety
Type
Thermal protector
devices
Operating temp.
Open
°C
130 ± 8
Close
Automatic reclosing
Run capacitor
µF
1.0
VAC
440
Type
Stepping motor
Model ... Q´ty
MP24GA2 ... 2
Rating
DC 12 V
Coil resistance (Ambient temp. 20°C)
k
Ω
Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.3
Face area
m2
0.214
Heat
Exch. Coil
Flap Motor
Fan & Fan Motor
Circuit Board Ass´y
Indoor Unit
SAP – K30
3
A